Installation
2-32 Manual # 42-02-2P24
Table 2.4 TorqMax F5 Parameters
Display
Parameter Description
Unit
Range
Default
Factory
WARNING:
Do not change drive parameters while the elevator is running. Incorrect drive
parameter values can cause erratic operation.
WARNING: Parameters with an asterisk (*) must be set correctly for your specific motor /
machine / job. Refer to the adjustment manual for detailed information.
LF. 2
Signal operating mode:
AbSPd - Absolute Analog Speed
d SPd - Digital Speed Selection
A tor - Analog Torque Control
A Spd - Analog Speed Control
SerSP - Serial Com. Speed Control
bnSPd - Binary Speed Selection
S POS – Serial Position feedback
-
AbSPd
d Spd
A tor
A Spd
SerSP
BnSPd
S POS
bnSPd
SerSP
LF. 3
Drive configuration:
run- run mode
conF - Configuration (5 minute time limit)
Stop - Drive stopped, Motor cannot run. Drive
will not respond. When using serial com,
this mode allows parameter changes
S Lrn - activate auto tune
I Lrn - Inertia Learn. Learns the system inertia
and activates the FFTC.
P Lrn: Pole Learn. Learn the pole positions of
PM Motor
SPI - Stationary Pole Learn. Learn absolute
encoder position for PM machine under
brake without sheave movement.
(N/A for software Version 1.61)
OStST - Over speed test function. Allows car to
over speed machine to test governor.
(N/A for software Version 1.61)
-
run
conF
Stop
S Lrn
I Lrn
P Lrn
SPI
OStST
conF
run
LF. 4
Motor-selection: Displays mode selected using US.
4 and US.10
ICLSd - Close loop induction
I9LSS = Closed loop induction gearless
PCLSd = Closed loop permanent magnet (PM)
P9LSS = Closed loop PM gearless
-
see US.10
-
***
LF. 5
Drive fault auto reset
1
0 - 10
5
5
LF. 8
Electronic motor overload protection
-
on, off
off
on
LF. 9
IM - Electronic overload current
PM - not visible, auto set same as LF.12
A
1.0 - 110%
Drive rated
8.0
*
LF.10
IM - Rated motor power
PM - read only, auto calc.
HP
0.00 - 125.00 5.00
*
LF.11
Rated motor speed
rpm
10.0 - 6000.0 1165 or
150
*
LF.12
Rated motor current
A
1.0 - 110%
Drive rated
8.0
*
LF.13
Rated motor frequency
Hz
4.0 - 100.0
60.0
*
LF.14
Rated motor voltage
IM - Name plate rated voltage
PM - No-load, phase-to-phase back EMF rms volt-
age at LF.11
V
IM: 120 - 500V
PM: 1 -
32000V/krpm
230/460
*
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...