OPERATION

If there is any electrical failure (of the fuse system, ground protection or transformer), turn 

off and unplug the unit immediately. Make sure the microscope is set aside so it will not be 

used again and contact the Motic service department or a Motic microscope repair agency 

to have it repaired.

Please be sure to turn off the power before opening the instrument to replace LED illuminator 

or replace the fuse! Only use a fuse for the rated current. Safety instructions for the use of 

immersion oil.

• Immersion oil is irritating to skin; avoid contact with skin, eyes and clothing.

• Skin contact: wash with soap and plenty of water until the immersion oil is completely 

removed.

• Eye contact: flush immediately with plenty of water for at least 5 minutes. If irritation 

persists, seek medical advice.

• Dispose of immersion oil properly. Do not discharge into surface water or sewage.

The biological microscope is not equipped with any special device to protect against corro-

sive, latent infective, toxic, radioactive or other hazardous samples. Therefore, when examin-

ing any such sample you must comply with the relevant laws and regulations, in particular 

the provisions related to accident prevention.

QUALITY WARRANTY

The SILVER150 Series biological microscope and the attached accessories are only allowed 

to be used for microscope examination as described in this manual. The manufacturer takes 

no responsibility for any other use.

•  The manufacturer guarantees that the product is free from any defect in material or 

workmanship on the date of delivery.

•  If any defect is found, notify the manufacturer immediately.

• Upon receipt of the Notification of Defect as described above, the manufacture is responsi-

ble to solve the problem either by repairing the defective instrument or replacing it with a new 

instrument of the same model.

• The manufacturer provides no warranty for any failure or defect due to normal wear and 

tear or improper use of the product.

•  The manufacturer takes no responsibility for any damage caused by operation error, 

negligence or unauthorized dismantling of the instrument, or the use of spare parts from 

other manufacturers.

SILVER

150

 

SERIES

 

|  03 

  

SAFETY INSTRUCTIONS

SILVER

 LINE

Summary of Contents for 1100104700013

Page 1: ...SILVER150 SERIES INSTRUCTION MANUAL ENGLISH SILVERLINE...

Page 2: ...uch the optical lens surfaces WASTE DISPOSAL Important Any damaged biological microscope must not be treated as general waste it should be disposed of according to relevant regulations OPERATION When...

Page 3: ...c radioactive or other hazardous samples Therefore when examin ing any such sample you must comply with the relevant laws and regulations in particular the provisions related to accident prevention QU...

Page 4: ...SERIES 04 SILVER150 SERIES The SILVER150 Series stands out for its innovation quality and student proof features offering a wide range of microscopes for educational purposes in high schools up to adv...

Page 5: ...binocular head and is designed to help compensate the difference between the user s eyes CONDESER The condenser is mounted in the stage and it is used in conjunction with the iris diaphragm The functi...

Page 6: ...tical path The nosepiece must click into place for the objectives to be in proper alignment OBJECTIVES The DIN objectives are standard in the industry with large numerical aperture N A to permit maxim...

Page 7: ...orts the stage and contains the coarse and fine adjusting knobs and focusing mechanism BASE The housing and platform of the instrument to which the arm is attached The base stands on rubber feet and c...

Page 8: ...cus decreases with the increase of numerical aperture or with the increase of magnification EYE POINT OR EYE RELIEF The distance from the eyepiece lens to your eye where a full field of view can be se...

Page 9: ...should be fully charged for approximately 8 hours before the initial use It can be charged by using the 4 5 volt A C adapter included with the microscope The battery can be used to power the illuminat...

Page 10: ...e focus tension has been set at the factory but can be readjusted as required OPERATION OF THE BIOLOGICAL MICROSCOPE Interpupillary distance adjustment 1 While looking through the microscope grasp the...

Page 11: ...efully refine the focus to clearly observe the fine details of the specimen 7 If the image of the specimen appears pale the aperture of the iris diaphragm should be slowly closed until the details of...

Page 12: ...t eye turn the left eye diopter only don t touch the focus controls to obtain a crisply focused image The diopter adjustment is now set and no further adjustment will be needed until a new operator us...

Page 13: ...ersion oil to use IMPORTANT The working distances of the 40XRD and 100XRD objectives to the slide surface are very small and although these objectives are sealed to prevent oil contamination it is a g...

Page 14: ...f the glass The finish of the microscope is hard epoxy and is resistant to acids and reagents Clean this surface with a damp cloth and mild detergent Periodically the microscope should be disassembled...

Page 15: ...view Is the Abbe condenser in the correct position Dust or hairs seem to be moving in the image The iris diaphragm is not open wide enough Slowly open the diaphragm to increase the size of the openin...

Page 16: ...epair by unauthorized parties accident alteration shipping misuse or abuse is not covered Warranty service is provided by Motic authorized technicians Determination of warranty is at the technician s...

Page 17: ...882 2792 Motic Europe S L U Spain Pol gon Industrial Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax 34 93 756 6287 CCIS is a trademark of Motic Incorporation Ltd...

Reviews: