background image

 

 

2. INSTRUMENT DESCRIPTION 
 

2.1 General Views 

Summary of Contents for 1100104100051

Page 1: ...ECO Series Instruction Manual WWW MOTIC COM MOTIC HONG KONG LIMITED...

Page 2: ...mes 6 2 3 Application 7 2 4 Instrument and its major features 7 3 FIRST TIME USE AND OPERATION 8 3 1 First time use 8 3 2 Operation of the biological microscope 10 3 2 1 Interpupillary distance adjust...

Page 3: ...ution Danger 1 2 Instrument safety The ECO microscope has been designed manufactured and inspected according to the GB 4793 1 2007 and IEC 61010 1 2001 Safety Requirements for Electrical Equipment for...

Page 4: ...kbench for operation Since the biological microscope is a precision instrument improper operation will impair or spoil its performance The power unit is integrated in the main unit of the biological m...

Page 5: ...vention 1 6 Quality Warranty The ECO microscope and the attached accessories are only allowed to be used for microscope examination as described in this manual The manufacturer takes no responsibility...

Page 6: ...5 2 INSTRUMENT DESCRIPTION 2 1 General Views...

Page 7: ...6 2 2 Parts names...

Page 8: ...pe include Binocular siedentopf inclined at 30 degrees and rotating or Monocular siedentopf inclined at 45 degrees and rotating Widefield WF10X 18mm eyepieces Quadruple nosepiece with parcentric click...

Page 9: ...avoid fingerprints Remove the microscope from the transport case and place it onto the worktable Retain the original packaging for storage of the instrument in longer periods of non use or for return...

Page 10: ...ion and then turn on or off the ON OFF switch Fig 3 Fig 3 Adjust the illuminator to the desired intensity Fig 4 Fig 4 After finishing work switch off the microscope and cover it with the dust cover Th...

Page 11: ...The adjustment of the interpupillary distance is correct when you see only one round image while looking through the two eyepieces Fig 6 Fig 6 3 2 2 Setting brightfield illumination First place a hig...

Page 12: ...ght intensity control on the microscope stand 3 3 Converting the microscope Note Unplug the plug in power unit from line power before converting the microscope 3 3 1 Replace the 12V 20W halogen bulb o...

Page 13: ...fingers as this will reduce bulb life If the stand is equipped with an LED source turn the focusing drive to move the mechanical stage fully up Unscrew the screws Fig 9a Take out the top part of the i...

Page 14: ...changed into a lateral position Unscrew the objective using the rubber strip included in the delivery and remove it downward Screw the desired objective hand tight into the nosepiece as far as it will...

Page 15: ...a brush rubber suction bulb and a moistened lens tissue Use only optical lens tissues and optical lens cleaner see below Never clean a lens with a dry optical lens tissue Be sure to remove any dust b...

Page 16: ...ocus the condenser Wrong cover glass thickness selected for use of transmitted light objectives corrected for 0 17mm cover glass Use standard 0 17 mm cover glass Use of no or non specified immersion o...

Page 17: ...fe of 12V 20W halogen lamp has been reached Replace the 12V 20W halogen lamp Power cable incorrectly installed or broken Connect the power cable correctly or replace it The pins of the 12V 20W halogen...

Page 18: ...and GmbH GERMANY Christian Kremp Strasse 11 D 35578 Wetzlar Germany Tel 49 6441 210 010 Fax 49 6441 210 0122 Motic Europe SPAIN C Les Corts 12 Pol Ind Les Corts 08349 Cabrera de Mar Barcelona Spain Te...

Reviews: