![Moteurs Baudouin PowerKit 6M16 Series Operation And Maintenance Manual Download Page 25](http://html1.mh-extra.com/html/moteurs-baudouin/powerkit-6m16-series/powerkit-6m16-series_operation-and-maintenance-manual_1837391025.webp)
Operation and Maintenance Manual for PowerKit 6M16 Series
25 of 40
5) Check the oil pressure of diesel engine;
6) Check the connector and wire connection;
7) Check the water temperature of diesel engine;
8) Check the temperature and color of exhaust gas, sound, vibration and speed of diesel engine.
Check the liquid level and coolant temperature
Check the coolant level through the glass sight hole. And if it is insufficient, open the filler port cap
to add coolant, as shown in Figure 3-1.
Notice: Before opening the filler cap, push down the air bleeding button to avoid personal injuries
by the hot coolant while the engine is hot.
Figure4-1 Coolant filler port cap
Check the oil level
It is not allowed to start the engine when the oil level is below the lower marking or above the upper
marking.
When checking the oil level, stop the engine and wait for at least 5 minutes, enabling the oil to flow
back to the oil pan.