23
‐
code 004 will show in the LCD screen. Charge the battery
immediately.
Battery Over Voltage Protection: When the battery voltage is too
higher, the charging input will automatically shut down.
Fault code
008 will show in the LCD screen.
Stop charging the battery
immediately and contact an authorized dealer.
7.2 OUTPUT PROTECTION
When AC output is overloaded (in excess of rated power) or short-
circuited, the AC output will automatically shut down.
The buzzer
alarm will sound 3 times uninterruptedly and the warning light
flashes 3 times at the same time. Reset the AC switch can recover
the AC output after reducing loads or eliminating short-circuited
problems.
DC output is overloaded or short-circuited: the DC output will
automatically shut down. Fault code 032 will show in the LCD
screen. Reset the main switch can recover the DC output after
reducing DC loads or eliminating short-circuited problems.
Inverter Over Temperature Protection: When the temperature in
the inverter is too higher, AC output will automatically shut down.
The buzzer alarm will sound 5 times uninterruptedly and the
warning light flashes 5 times at the same time. Turn off the
electrical appliance connected to the mobile power, and put the
mobile power in a cool place to cool it then reset the AC switch.
Over Temperature Protection: When the temperature in the mobile
power is too higher, the charging input, DC and AC output will
automatically shut down. Fault code 016 will show in the LCD
screen. Over temperature light comes on at the same time. Turn
off the electrical appliance connected to the mobile power, and put
the mobile power in a cool place to cool it then reset the main
switch.