background image

MORTEX

 

PRODUCTS

 

INC

 

FORT

 

WORTH,

 

TX

 

76106

 

Page

 

18

 

SPD

 

TAP

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

LO

1225

1174

1121

1077

1036

976

924

877

740

629

MED

LO

1429

1386

1345

1308

1245

1220

1158

1115

1070

608

MEDIUM

1569

1529

1476

1438

1403

1368

1313

1260

1109

707

MED

HI

1785

1740

1711

1664

1619

1592

1488

1359

1137

967

HI

2129

2057

2017

1959

1838

1733

1603

1432

1225

1183

CFM

 

with

 

Coil

 

LO

1104

1059

1012

975

930

876

780

719

662

581

98

8W7W

OP

 

MED

LO

1292

1244

1214

1184

1136

1098

1053

981

773

584

a nd

 

Cabinet

 

MEDIUM

1400

1365

1334

1301

1263

1219

1168

1070

780

592

97

FLSB

27

 

MED

HI

1596

1569

1521

1468

1392

1301

1204

1087

811

604

or

 

97

FLSF

27

HI

1743

1659

1615

1505

1425

1341

1236

1106

809

582

CFM

 

with

 

Coil

 

LO

1067

1017

978

942

889

805

758

703

661

518

98

8W7W

OP

 

MED

LO

1268

1229

1199

1158

1109

1075

1012

826

675

536

with

 

Cabinet

MEDIUM

1374

1343

1311

1278

1224

1163

1053

812

708

524

97

FSOB

27

MED

HI

1549

1481

1409

1338

1258

1189

1087

848

669

481

HI

1611

1529

1460

1383

1297

1199

1115

889

708

578

CFM

 

with

 

Coil

 

LO

1104

1085

1025

979

936

882

786

719

682

580

98

8W12W

OP

 

MED

LO

1309

1266

1232

1197

1156

1119

1074

1010

790

606

with

 

Cabinet

MEDIUM

1429

1390

1350

1323

1281

1234

1203

1124

801

629

97

FLSB

39

 

MED

HI

1607

1573

1539

1497

1430

1332

1256

1152

815

637

or

 

97

FLSF

39

HI

1751

1663

1607

1533

1455

1372

1270

1160

811

619

CFM

 

with

 

Coil

 

LO

1104

1059

1023

974

935

902

841

723

676

563

98

8W12W

OP

MED

LO

1285

1246

1211

1175

1126

1104

1065

874

711

561

 

with

 

Cabinet

MEDIUM

1404

1350

1327

1294

1251

1211

1145

1005

718

535

97

FSOB

39

MED

HI

1601

1538

1468

1400

1327

1241

1148

888

719

541

HI

1725

1613

1530

1442

1360

1283

1190

1088

739

576

CFM

 

with

 

Coil

 

LO

1111

1072

1019

976

931

877

781

712

680

548

98

8G12W

OP

 

MED

LO

1289

1255

1226

1185

1143

1105

1066

938

732

556

with

 

Cabinet

MEDIUM

1415

1367

1345

1308

1270

1226

1170

1072

751

573

97

FLSB

39

 

MED

HI

1594

1571

1519

1449

1380

1294

1205

1043

736

551

or

 

97

FLSF

39

HI

1716

1643

1563

1511

1411

1317

1228

1088

748

596

CFM

 

with

 

Coil

 

LO

1084

1038

996

952

899

813

748

705

823

494

98

8G12W

OP

MED

LO

1262

1227

1187

1150

1112

1067

1014

775

621

488

 

with

 

Cabinet

MEDIUM

1373

1341

1314

1265

1207

1134

1032

807

638

489

97

FSOB

39

MED

HI

1513

1455

1373

1309

1247

1150

1067

793

672

509

HI

1557

1484

1417

1337

1271

1172

1055

835

885

533

CFM

 

with

 

Coil

 

LO

1106

1072

1026

969

938

878

774

721

676

532

98

8Z12W

OP

 

MED

LO

1299

1266

1222

1186

1139

1100

1057

938

752

539

with

 

Cabinet

MEDIUM

1416

1377

1341

1309

1271

1241

1181

1067

740

539

97

FLSB

39

 

MED

HI

1603

1588

1540

1476

1390

1336

1232

1095

748

545

or

 

97

FLSF

39

HI

1741

1667

1607

1532

1435

1350

1253

1148

1165

558

CFM

 

with

 

Coil

 

LO

1088

1019

1007

967

924

870

824

716

621

507

98

8Z12W

OP

MED

LO

1270

1240

1200

1143

1110

1077

990

747

612

496

 

with

 

Cabinet

MEDIUM

1371

1340

1303

1265

1210

1138

1019

796

627

506

97

FSOB

39

MED

HI

1555

1487

1424

1331

1270

1148

1037

792

675

494

HI

1613

1543

1445

1385

1279

1200

1083

924

700

507

EXTERNAL STATIC PRESSURE (ESP) INCHES WC DUCT

CFM

NO

COIL

 

 

Table 6: Blower Performance -10 X 9 Morrison Wheel - 3/4 HP 5 SPD X-13 Motor (With Air filters) 

Summary of Contents for E30A2D0008ABA

Page 1: ...21 2 Factory Speed Tap Settings 13 9 Accessory Parts List 22 3 Blower Performance 1 3 HP PSC Motor 14 10 Replacement Parts List 1 3 HP PSC Motor 23 4 Blower Performance 1 3 HP X 13 Motor 15 11 Replacement Parts List 1 3 HP X 13 Motor 24 5 1 Blower Performance 1 2 HP X 13 Motor 16 12 Replacement Parts List 1 2 HP X 13 Motor 25 5 2 Blower Performance 1 2 HP X 13 Motor 17 13 Replacement Parts List 3 ...

Page 2: ...ow of air is required for safe and proper operation Never block or obstruct air openings used for ventilation and cooling of the furnace electrical components 8 Refer to the furnace rating plate for the furnace model number for the operating specifications for safe operation 9 Provide clearances for servicing ensuring service access is allowed for the control box electric elements and the blower 1...

Page 3: ...hnician The furnace s best friend is a qualified service technician If the unit gives any indication of improper operation call the service technician The service technician is allowed to perform the normal routine care of your furnace He can detect potential problems and make corrections before trouble develops Preventative maintenance of this type will allow the furnace to operate with minimal c...

Page 4: ...area If you smell vapors of any kind DO NOT turn on the power to the furnace until vapors have been ventilated and removed from the area of the furnace B CHECK THE FURNACE visually check the furnace for loose screws and or panels that may be missing or have fallen off C CHECK DUCT CONNECTIONS visually check the connections of the ducts to the furnace to make sure there are no gaps or holes and duc...

Page 5: ...efer to Figure 5 11 Follow the instructions to Turn On Start the Appliance in the Startup and Shutdown section of these instructions 12 Follow the instructions to Turn On Start the Appliance in the Startup and Shutdown section of these instructions Coil Cabinet Top Air Filters Follow these easy steps to replace the filters located in the top of the coil compartment 1 Follow the procedure To Turn O...

Page 6: ...instructed as to how to clean and reinstall filters washable or replaceable filters for good preventive maintenance Care must be taken that the edges of the washable or replaceable filter are resting on the protruding edges of the metal plates at each end of the aluminum fins This allows a gap between the filter and the coil surface to prevent dirt from wicking from the filter to the coil Make sur...

Page 7: ...serious injury if clothing or body parts get caught in the moving part The manufacturer or distributer will not be responsible for any repairs due to improper parts changes improper maintenance improper furnace adjustments or improper modifications made by the homeowner and or the appliance user The manufacturer will not be responsible if the homeowner and or appliance user use this section of the...

Page 8: ... dirt or debris from around the heater elements Be careful not to damage the heater elements with the vacuum hose or the brush Figure 7 Control Box Cover Figure 8 Blower Assembly and Mounting Screw Location 8 Check the blower wheel for dust and debris Use the brush and the vacuum cleaner to remove any dust or debris from the wheel Be careful not the move or accidentally remove the blower wheel bal...

Page 9: ...or isolation between the high and low speeds of a PSC motor The wiring has been designed so that the normally closed contacts are used for heating and the normally open contacts are used for cooling The relay coil is energized after the thermostat has a call from the G terminal starting the time delay cycle on the time delay relay Once the time delay relay has reached the delay setting the relay c...

Page 10: ...ing Cycle When the thermostat calls for cooling The thermostat closes the circuit between the R Y and G terminals 24 VAC is sent from the Y terminal through the yellow thermostat wire to the 24 VAC coil terminal on the condenser contactor energizing the contactor and starting the compressor and outdoor fan motor At the same time the G terminal is sending 24 VAC through the green pigtail wire to th...

Page 11: ...240 VAC and 24 VAC at the motor terminals A If the 240 VAC and 24 VAC is present at the motor terminals but the motor is not operating then replace the motor Refer to Figure 12 and Table 1 for terminal locations and definitions B If 240 VAC is not present at the motor check for a broken wire between the circuit breaker number one and the motor C If 240 VAC is present at the motor terminals continu...

Page 12: ... to OFF 3 Disconnect the plastic wire plug that has the wires that goes to the motor terminals from the top right side of the control box 4 Remove the two screws on the right side of the blower mounting plate 5 Slide the blower out of the blower compartment and set on the floor 6 Remove the wires from the terminals Be sure to write down the motor terminal identifier and wire color so the wires do ...

Page 13: ... 8 R M Z 2 3 4 5 G 8 W 11 14 P 330 1680 7 56 223 98 8 R M Z 2 3 4 5 G 8 W 12 15 P 330 1680 8 00 210 98 8 R M Z 2 3 4 5 G 8 W 13 17 P See Example 330 CFM kW x 3412 x Voltage Correction Less Than 240V x 1 08 TR E30B3DxxxAAA Electric Furnace temperature rise TR can be used to determine air flow delivered This result can then be used to determine FPMvelocityacross the coil face area using the chart be...

Page 14: ...5 952 949 946 928 890 724 648 532 364 with Cabinet97 FLSB 27 MEDIUM 1175 1170 1164 1143 1100 1025 964 716 558 405 or 97 FLSF 27 HI 1536 1463 1403 1328 1249 1155 1075 900 716 493 CFMwith Coil 98 8G7W OP LO 1010 1013 1001 975 930 874 688 587 463 363 with Cabinet97 FSOB 27 MEDIUM 1205 1184 1153 1110 1048 975 751 640 496 367 HI 1553 1482 1407 1328 1244 1154 1039 747 608 438 CFMwith Coil 96 8G4W OP LO ...

Page 15: ...6 LO 764 689 586 507 460 399 332 MED LO 855 807 733 632 571 521 478 416 367 MEDIUM 990 923 878 825 741 672 628 574 520 440 MED HI 1085 1031 988 929 878 789 725 663 603 474 HI 1291 1247 1202 1160 1117 1073 1020 821 665 524 CFM with Coil LO 721 655 566 507 451 374 315 98 8G7W OP MED LO 828 756 705 623 561 529 462 404 359 with Cabinet MEDIUM 948 898 845 778 705 641 595 553 502 406 97 FSOB 27 MED HI 1...

Page 16: ...656 630 494 with Cabinet MEDIUM 1251 1216 1170 1134 1079 1045 1009 860 685 570 97 FLSB 27 MED HI 1450 1410 1380 1335 1303 1221 1139 1056 737 580 or 97 FLSF 27 HI 1549 1506 1457 1410 1335 1246 1165 1056 741 648 CFM with Coil LO 878 811 771 714 625 558 536 478 417 377 98 8W7W OP MED LO 1035 981 943 891 852 797 702 652 609 474 with Cabinet MEDIUM 1223 1190 1151 1111 1072 1018 940 842 647 523 97 FSOB ...

Page 17: ...1316 1245 1137 1012 679 551 or 97 FLSF 39 HI 1570 1531 1488 1415 1344 1279 1170 1070 736 562 CFMwith Coil LO 851 813 759 708 618 555 523 458 394 362 98 8Z12W OP MED LO 1021 982 934 884 837 740 684 636 573 452 with Cabinet MEDIUM 1210 1170 1138 1092 1052 999 922 751 613 469 97 FSOB 39 MED HI 1419 1385 1344 1279 1210 1083 1010 774 621 480 HI 1503 1458 1393 1312 1230 1103 1019 785 629 486 CFMwith Coi...

Page 18: ...126 1104 1065 874 711 561 with Cabinet MEDIUM 1404 1350 1327 1294 1251 1211 1145 1005 718 535 97 FSOB 39 MED HI 1601 1538 1468 1400 1327 1241 1148 888 719 541 HI 1725 1613 1530 1442 1360 1283 1190 1088 739 576 CFM with Coil LO 1111 1072 1019 976 931 877 781 712 680 548 98 8G12W OP MED LO 1289 1255 1226 1185 1143 1105 1066 938 732 556 with Cabinet MEDIUM 1415 1367 1345 1308 1270 1226 1170 1072 751 ...

Page 19: ...97 641 608 521 393 98 8W7W OP MEDIUM 1271 1222 1166 1117 1055 983 796 721 634 565 with Cabinet HI 1438 1369 1304 1232 1166 1090 1008 811 705 615 97 FSOB 27 CFM with Coil LO 932 919 913 893 860 808 752 674 555 450 98 8W12W OP MEDIUM 1336 1303 1279 1234 1172 1111 1030 948 793 678 with Cabinet HI 1683 1615 1552 1465 1386 1303 1208 1100 987 771 97 FLSB 39 or 97 FLSF 39 CFM with Coil LO 961 934 902 863...

Page 20: ...4 637 553 with Cabinet HI 1448 1387 1314 1242 1175 1094 1006 916 732 578 97 FSOB 39 CFMwith Coil LO 946 940 913 890 850 807 701 613 555 445 96 8W4W OP MEDIUM 1319 1279 1229 1192 1155 1080 991 897 711 552 with Cabinet HI 1590 1534 1467 1396 1313 1223 1127 1028 904 731 97 FLSB 21 or 97 FLSF 21 CFMwith Coil LO 942 920 885 835 789 708 630 573 494 364 96 8W4W OP MEDIUM 1264 1203 1150 1090 1025 950 883 ...

Page 21: ...862 622 474 98 8W12W OP MEDIUM 1502 1440 1370 1302 1240 1153 1059 950 823 523 with Cabinet HI 1599 1530 1457 1388 1314 1244 1355 1039 762 566 97 FSOB 39 CFM with Coil LO 1412 1372 1326 1278 1214 1145 1067 951 713 504 98 8G12W OP MEDIUM 1643 1577 1505 1438 1358 1288 1203 1107 983 684 with Cabinet HI 1747 1672 1605 1529 1443 1358 1275 1176 1056 688 FLSB 39 or 97 FLSF 39 CFM with Coil LO 1352 1301 12...

Page 22: ...C 5 TON ACCESSORY BLOWER 86MH0026 3 4 HP X 13 5 TON ACCESSORY BLOWER 86MH0027 21 1200 CFM BROKE DOWN COOLING COIL CABINET 97 FLSB 21 21 1600 CFM BROKE DOWN COOLING COIL CABINET 97 FSOB 21 21 1800 CFM BROKE DOWN COOLING COIL CABINET 97 FLOB 21 31 1600 CFM BROKE DOWN COOLING COIL CABINET 97 FLSB 27 31 1600 CFM BROKE DOWN COOLING COIL CABINET 97 FSOB 27 31 1800 CFM BROKE DOWN COOLING COIL CABINET 97 ...

Page 23: ...17 R68BAD018 R68BAD014 R68BAD018 R68BAD018 6 CIRCUIT BREAKER 2 R68BAD013 R68BAD013 R68BAD017 7 HEATER CONTACTOR 1 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 8 HEATER CONTACTOR 2 R68AB0019 R68AB0019 R68AB0019 9 TIME DELAY RELAY R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 10 LIMIT 155 F R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 11 GROUND LUG R68GF00...

Page 24: ...IRCUIT BREAKER 1 R68BAD014 R68BAD017 R68BAD018 R68BAD014 R68BAD018 R68BAD018 7 CIRCUIT BREAKER 2 R68BAD013 R68BAD013 R68BAD017 8 HEATER CONTACTOR 1 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 9 HEATER CONTACTOR 2 R68AB0019 R68AB0019 R68AB0019 10 TIME DELAY RELAY R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 11 LIMIT 155 F R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0...

Page 25: ... BREAKER 1 R68BAD014 R68BAD017 R68BAD018 R68BAD014 R68BAD018 R68BAD018 7 CIRCUIT BREAKER 2 R68BAD013 R68BAD013 R68BAD017 8 HEATER CONTACTOR 1 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 9 HEATER CONTACTOR 2 R68AB0019 R68AB0019 R68AB0019 10 TIME DELAY RELAY R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 11 LIMIT 155 F R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 R6...

Page 26: ... BREAKER 1 R68BAD014 R68BAD017 R68BAD018 R68BAD014 R68BAD018 R68BAD018 7 CIRCUIT BREAKER 2 R68BAD013 R68BAD013 R68BAD017 8 HEATER CONTACTOR 1 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 9 HEATER CONTACTOR 2 R68AB0019 R68AB0019 R68AB0019 10 TIME DELAY RELAY R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 11 LIMIT 155 F R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 R6...

Page 27: ...68BAD014 R68BAD018 R68BAD018 6 CIRCUIT BREAKER 2 R68BAD013 R68BAD013 R68BAD017 7 HEATER CONTACTOR 1 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 8 HEATER CONTACTOR 2 R68AB0019 R68AB0019 R68AB0019 9 TIME DELAY RELAY R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 10 LIMIT 155 F R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 11 GROUND LUG R68GF0022 R68GF0022 R...

Page 28: ...1 R68BAD014 R68BAD017 R68BAD018 R68BAD014 R68BAD018 R68BAD018 8 CIRCUIT BREAKER 2 R68BAD013 R68BAD013 R68BAD017 9 HEATER CONTACTOR 1 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 R68AB0019 10 HEATER CONTACTOR 2 R68AB0019 R68AB0019 R68AB0019 11 TIME DELAY RELAY R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 R68AC0009 12 LIMIT 155 F R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 R68CA0008 ...

Reviews: