background image

1

1

MORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORS

E-Mail: [email protected] · Website: www.morsoe.com

A French version of the manual can be downloaded at www.morsona.com

Une version française du manuel peut être téléchargé à www.morsona.com

Installation and Operating Instructions

6100 series

For use in North America

Read this entire manual before you install and use your new room heater. If this room heater is 
not properly installed, a house fire may result. To reduce the risk of fire, follow the installation 
instructions. Failure to follow instructions may result in property damage, bodily injury, or 
even death.

Contact local building officials about restrictions and installation/inspection-requirements 
in your area. 

Save these instructions

Summary of Contents for 6100 series

Page 1: ...ctions 6100 series For use in North America Read this entire manual before you install and use your new room heater If this room heater is not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local building officials about restrictions and insta...

Page 2: ...sø 6100 series meets the U S Environmental Protection Agency s emission limits for wood heaters sold on or after July 1 1990 The Morsø 6100 series have been tested by OMNI Test Laboratories Inc The test standards are ANSI UL 1482 for the United States and ULC S627 for Canada The stove is listed for burning wood only Do not burn other fuels Under specific test conditions this heater has been shown ...

Page 3: ...xisting chimney 6 1 5 Positioning the stove 8 1 6 Mobile Home Installation 10 2 0 Operation 11 2 1 Before you start firing 11 2 2 Lighting and loading intervals 12 3 0 Maintenance 16 3 1 Exterior maintenance 16 3 2 Internal maintenance 16 3 3 Cleaning the stove and the flue 18 3 4 Leaving the stove for extended periods 21 3 5 Parts diagram 22 3 6 Parts list 23 ...

Page 4: ...he local building officials about restrictions and installation inspection in your area Before you start installing your stove make sure that The stove and chimney connection are placed far enough from combustible materials to meet all clearance requirements The floor protection must be adequate and must be made correctly according to the requirements All neccessary approvals are needed from the l...

Page 5: ...sions of the chimney connector and chimney must not be less than 6 inches diameter or equivalent cross section and should not be significantly larger than this Too large a section will tend to allow the flue gases to cool excessively causing sluggishness or unpredictability in the stove s performance We recommend the length of the chimney system should be at least 16 feet not required above the st...

Page 6: ...ope horizontal runs of connector upward 1 4 inch per foot 20 mm per metre going from the stove toward the chimney The recommended maximum length of a horizontal run is 3 feet 1 metre and the total length should be no longer than 8 feet 2 5 metres Information on assembling and installing connectors is provided by the manufacturer s instructions exactly as you assemble the connector and attach it to...

Page 7: ...7 ...

Page 8: ...above the stove see below in the clearance chart These distances may need to be increased if the materials are sensitive to heat Note also that wall paper and other decorative materials may become detached with the effects of heat and care should be taken to ensure that they do not fall towards the stove in such an event When the stove is positioned near non combustible materials a gap of 4 inches...

Page 9: ...LE FLOOR PROTECTOR FLOOR PROTECTION REQUIREMENTS NON COMBUSTIBLE MATERIALS BENEATH STOVE USA CANADA 8 8 16 8 200 mm 8 200 mm 8 200 mm 18 450 mm EXTENDING DISTANCE BACK EXTENDING DISTANCE RIGHT SIDE EXTENDING DISTANCE LEFT SIDE EXTENDING DISTANCE FRONT ...

Page 10: ...oor protection requirements in section 1 5 must be followed precisely In Canada this appliance must be connected to a 6 152 mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS Floor protection as referenced in section 1 5 must be followed as well as use of Canadian Floor Protector Follow the chimney and chimney connector manufacturer s instructions when installi...

Page 11: ...SENE CHARCOAL LIGHTER OR FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS AWAY FROM THE HEATER WHILE IT IS IN USE Note Acid Protection If acid washing the masonry around the stove protect the stove surface with an acid proof cover Fresh Air Inlet Unless there is deemed to be sufficient ambient leakage of air into the room via doorways windows and the like...

Page 12: ...Pilot air inlets Primary Air is controlled using the lever situated over the door Moving the control lever to right position will open the air inlet and will allow a supply of preheated air to enter the firebox via the airwash system situated inside the stove and above the glass Choosing your fuel All types of natural wood can be burned on your stove but they must be well seasoned and dry Once the...

Page 13: ... quickly be formed by lighting with firestarters Morsø kindling bags or 7 10 pieces of twisted paper under the dry kindling wood 4 After lighting partially close the door leaving it open an inch or two to allow in plenty of combustion air 2 For lighting the fire use 2 3 pounds of dry kindling wood ...

Page 14: ... embers Leave half an inch or more between each piece Max fuelload 4 0 pounds h 8 Close the door Leave the primary air supply fully open If it does not light leave the door slightly ajar to allow the necessary amount of air in to ignite the wood Close the door again once the wood has kindled 9 After a few minutes adjust the primary air supply to suit your heating requirements Make sure that there ...

Page 15: ...ter part 62901200 The Flue Gas Thermometer magnetically attaches onto the stove pipe approx 20 cm 8 above the stove s top plate and measures the surface temperature of the stove pipe Please see your authorized Morsø Dealer for availability Draft conditions If smoke or fumes come out of your stove when lightning up and reloading or if the fire simply will not respond a poor draft is almost certainl...

Page 16: ...n perfoming maintenance on your stove always protect yourself using safety goggles and gloves 3 1 Exterior Maintenance The stove surface is painted with heat resistant Senotherm paint It is best kept clean by vacuuming with a soft brush attachment or by wiping with a lint free cloth Over a period of time the painted surface may become slightly grey A can of Morsø touch up spray paint should be ava...

Page 17: ...h hinge Remove the two hinge pins lift the door off the hinges and place it face down on a sheet of cardboard or other nonabrasive fabric 2 Unscrew the 4 bolts that secure the glass In the event that a bolt sheers off when being unscrewed remove the remaining body of the bolt by drilling down its centre with 1 8 inch high speed steel drill bit Smaller drill bits may be successful but do not use a ...

Page 18: ...way from the stove to the flue terminal point above the house A good routine is to clean the flue after each heating season in any case and inspect prior to the season to ensure that bird s nests or other blockages have not occurred during the off season Ash disposal Empty the ashpan on a daily basis or as needed Ash allowed to build up towards the underside of the grate will trap heat and could c...

Page 19: ...Morsø Dealer or a professional chimney sweep If you do experience a chimney fire act promptly and Close the air control Get everyone out of the house Call the Fire Department Annual maintenance Before the heating season perform a thorough cleaning inspection and repair Thoroughly clean the chimney and chimney connector Inspect the chimney for damage and deterioration Replace weak sections of prefa...

Page 20: ...re chamber 3 Tip the other side brick and remove it from the fire chamber 4 When the side bricks are removed the bottom baffle is lowered and lifted out of the fire chamber 5 The upper baffle is removed from the brackets and lifted out of the firechamber ...

Page 21: ...o settle within the stove rust will form Rust expands as it takes a grip This can lead to undue pressure on the stove joints and this in turn may result in damage to the stove NOTE It is best to thoroughly clean the stove after the heating season has concluded Adding a dessicant such as kitter litter into the ash pan helps absorb moisture during the summer months Be sure to remove this prior to th...

Page 22: ...22 3 5 Parts diagram for model Morsø 6100 ...

Page 23: ...44256800 44256800 22 Washer 791891 791891 791891 23 Air canal top 446113xx 446113xx 446113xx 24 Air canal front 446116xx 446116xx 446116xx 25 Baffle plate lower 79610500 79610500 79610500 26 Baffle plate top 79610600 79610600 79610600 27 Handle 75610061 75610061 75610061 28 Hinge pin 542056 542056 542056 29 Screw 73950500 73950500 73950500 30 Handle f sek draught control 71611261 71611261 71611261...

Page 24: ...731608 60 Screw 731640 731640 731640 61 Screw 74361000 74361000 74361000 62 Screw 731635 731635 731635 63 Screw 731630 731630 731630 64 Tape for glass 79074200 79074200 79074200 65 Bottom plate 446115xx 446115xx 66 Pedestal 546115xx 67 Screw 731625 68 Washer 791891 69 Distance tube 541440 541440 541440 70 Washer 746206 746206 746206 71 Flue collar 441419xx 441419xx 441419xx 72 Stop bar 71611800 71...

Reviews: