WARNING

 - Watch Out for Pinch Points

Stay clear of moving parts.  Operator should 

remain behind the push handle during the lift 

operation.

Floor Lock

The screw-down floor lock is located on the base of the tower 

(figure 3.1).  Turning the floor lock clockwise until it locks in the 

down position activates the floor lock.  When the floor lock is 

activated it prevents unwanted free wheeling of the unit.  Floor 

conditions determine the effectiveness of the floor lock.  The 

operator should verify its holding action before depending on it to 

hold.

Drum Holder Assembly

The MORCINCH

TM

 Drum Holder (Saddle) assembly is the 

component on intended to hold the drum.  It is designed to secure 

a standard ribbed 55-gallon (210 liter) steel drum around it’s middle 

using a cinch chain and ratchet tightening system.  It automatically 

adjusts for 22” to 23.5” (56 to 59.7 cm) diameter drum.

The MORCINCH

TM

 Drum Holder also accepts accessories to 

handle a plastic drum, fiber drum, or a smaller diameter drum.

Figure 3.1

Figure 2.3

Controls

The Morse Hydra-Lift Karrier is manually propelled and steered. The drum lift 

and tilt controls are powered by a 12V DC motor with a momentary switch.

There are two functions for the operator to control (Figure 2.1):

1. “LIFT” and lower function for vertical positioning of the drum

2. “TILT” function to control the degree of rotation of the drum

1. LIFT and Lower Function

To raise the drum

a. Turn the motor on by holding the momentary switch in the on position.

b. With the motor on, raise the LIFT handle. 

To lower the drum

a. With the motor off, push in the LOWER handle.

2. TILT Function

To tilt the drum forward for pouring

a. Turn on the motor by holding momentary switch in the on position.

b. With the motor on, raise the tilt handle.

To return the drum to vertical position

a. Turn on the motor by holding momentary switch in the on position.

b. Push the tilt handle down.

Summary of Contents for 400A-72-115

Page 1: ...ping a digital camera at your receiving dock for this purpose Open packages expeditiously to check the condition of the goods There is only a 24 hour window to notify the carrier of any con cealed damage IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING COMPANY Then you may contact Morse for assistance with your freight claim Morse Manufacturing will not be held responsible for any dam aged freight th...

Page 2: ...s strewn floors WARNING Do Not Modify the Unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations may result in injury to operator or machine WARNING No Loose Fitting Clothing Wear close fitting clothing and safety equipment appropria...

Page 3: ...pter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to prevent drum slipping length ways NOTE For 30 gallon 114 Liter PLASTIC drum insert Diameter Adapter AND install Bracket or Top Rim Clamp to prevent drum slipping IMPORTANT To prevent 30 to 55...

Page 4: ...d 55 gallon 210 liter steel drum around it s middle using a cinch chain and ratchet tightening system It automatically adjusts for 22 to 23 5 56 to 59 7 cm diameter drum The MORCINCHTM Drum Holder also accepts accessories to handle a plastic drum fiber drum or a smaller diameter drum Figure 3 1 Figure 2 3 Controls The Morse Hydra Lift Karrier is manually propelled and steered The drum lift and til...

Page 5: ...cinch chain from ratchet by applying pressure to ratchet handle in clockwise direction with one hand and opening pawl to free ratchet with other hand Remove cinch chain link from ratchet START UP Procedure Machine is shipped with hydraulic fluid 1 Install provided hydraulic control levers threaded rods with black ball handles 2 IMPORTANT BEFORE operation remove the RED shipping plug from the hydra...

Page 6: ...er function Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level and condition of the hydraulic fluid Replace any parts that show signs of wear Grease wheel bearings periodically Oil or grease all moving parts including the three clevis pins and the surfaces of the boom which contact the inside of the mast cap the hinge pin the gears and sprockets in the ...

Reviews: