background image

The Specialist In Drum Handling Equipment

Model 400A-60-120

Hydra-Lift, 60”, AC Power Lift, Manual Tilt

Operator’s Manual for Morse Hydra-Lift Karrier Model 400A-60-120

Serial Number 1210 to ____ (MMYY)

morsedrum.com

Copyright 2019 - Morse Mfg. Co., Inc. 

 

Form PL400A-60-120 (1210-____)  

(Updated 18 Jun, 2021)

 

5

CAUTION

 

– Do Not Transport with Drum Raised

ALWAYS LOWER THE DRUM HOLDER TO LOWEST POSITION BEFORE TRANSPORTING. 

 The 

unit can become unstable when transporting with a raised load.

5.) Lift drum to desired pouring height.  Operate the tilt control as described in 

“Machine Description - Controls”

 (page 

3) to adjust the drum attitude. This is especially important when lifting an open drum.  The floor lock should be engaged 

while dispensing / draining.

6.) When dispensing is complete, tilt drum back to upright position.  Disengage the floor lock and lower the drum to trans

-

porting height; about 6” (15 cm) off the floor.

WARNING

 - Stay Clear of Raised Drum

NEVER allow anyone to be below any part of a raised drum handler or drum.  Remain behind 

the push handle while handling a drum.

WARNING

 – Do NOT Disengage the Cinch Chain When Drum is off the Ground

When the drum is in the upright position, lower the drum to the floor before releasing the cinch 

chain.

7.) Push the unit to the drum storage area and lower to the floor in an upright position.  Release the cinch chain from the 

ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free 

the ratchet with the other hand.  Remove the cinch chain link from the ratchet.

Maintenance

Periodic inspection for the general condition of structural and mechanical components is imperative for safe and efficient 

operation.

Periodically inspect all moving parts, framework, and contact areas for signs of wear, fatigue, or loosening.  Tighten, adjust, 

or replace parts as necessary to prevent failure and maintain proper function.

Inspect the hydraulic system for oil drips, hose damage, or other signs of wear.  Inspect the level and condition of the hy

-

draulic fluid.  Replace any parts that show signs of wear.

Grease wheel bearings periodically. Oil or grease all moving parts including: the three clevis pins and the surfaces of the 

boom which contact the inside of the mast cap, the hinge pin, the gears and sprockets in the tilt drive, and the ratchet and 

pawl.

Worn or damaged parts must be properly replaced with the correct, genuine Morse parts.

Hydraulic pump is shipped filled with Noco Premium plus automatic transmission fluid d/m. Material safety data sheet 
(msds) is available online. Change oil yearly, sooner depending on dirty conditions or outdoor use.

 

Replace oil with Mobil 

dte 24 or equivalent for indoor use (Mobil dte 13 for outdoor use).

WARNING

 - Watch Out for Pinch Points

Stay clear of moving parts.  Operator should remain behind the push handle during the lift operation.

Summary of Contents for 400A-60-120

Page 1: ...al camera at your receiving dock for this purpose Open packages expeditiously to check the condition of the goods There is only a 24 hour window to notify the carrier of any concealed damage IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING COMPANY Then you may contact Morse for assistance with your freight claim Morse Manufacturing will not be held responsible for any damaged freight that is not sign...

Page 2: ... only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Do Not Modify the Unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations may result in injury to o...

Page 3: ... is 800 Lb 363 kg The capacity is derated to 500 Lb 227 kg for a half full drum The half full rating is based on the tilt mechanism s capacity for handling an unbalanced bottom heavy drum Options 55 30 Series Diameter Adapters for smaller drum To handle a smaller drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products di...

Page 4: ...s activated it prevents unwanted free wheeling of the unit Floor conditions determine the effectiveness of the floor lock The operator should verify its holding action before depending on it to hold MORCINCHTM Drum Holder Assembly The drum holder assembly or saddle assembly is the component on the Hydra Lift Karrier that is intended to hold the drum The MORCINCH drum holder assembly is designed to...

Page 5: ...ase the cinch chain from the ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free the ratchet with the other hand Remove the cinch chain link from the ratchet Maintenance Periodic inspection for the general condition of structural and mechanical components is imperative for safe and efficient operation Periodically inspect all movin...