safety Information

 (continued)

DAnGeR 

- Indicates a situation which, if not avoided, will result in serious injury or death.  

This signal word is limited to the most extreme situations.

WARnInG 

- Indicates a situation which, if not avoided, could result in serious injury or 

death.

CAUtIon 

- Indicates a situation which, if not avoided, can result in damage to the machine.

WARnInG 

- Do Not Modify the Unit. Under no circumstances should any modifications be made to the Morse 

machinery without factory authorization.  Any modifications may void the warranty.  This machine was designed to 

perform a specific job and alterations may result in injury to operator or machine.

WARnInG 

- No Loose Fitting Clothing. Wear close-fitting clothing and safety equipment appropriate to the job.  

Loose fitting clothing may become caught on the machinery and cause severe personal injury.

CAUtIon 

- Wear safety shoes with non-slip soles and hard toe protection.

CAUtIon 

-  DO NOT allow drum to impact on floor, ground, or dumping station, etc.

WARnInG 

- Verify the chemical compatibility of the materials of your pump with the liquid you want to pump. If 

you are uncertain regarding chemical compatibility, contact your dealer for applications assistance and request a 

copy of our Corrosion Resistance Charts. Do not use a pump that is not chemically compatible with the liquid you 

intend to pump or serious bodily injury, death, fire, explosion or environmental damage could result. See 

Chemical 

Compatibility Chart

 online.

IMPoRtAnt 

- Refer to Chemical Resistance Data Chart for compatibility of materials. Always wear protective 

safety clothing such as gloves, apron, goggles. 

DAnGeR 

- When pumping flammable or combustible liquids from one container to another, both containers must 

be effectively bonded and grounded to prevent discharge of sparks or static electricity which could cause explosion 

and bodily harm.

WARnInG: 

This product can expose you to chemicals including cobalt, titanium dioxide, and 2-methylimidazole, 

which are known to the State of California to cause cancer, and bisphenol-A, which is known to the State of 

California to cause birth defects or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov

Summary of Contents for 26

Page 1: ...tem 21 1 nozzle item15 2 hose clamps item16 4 1 suction tube item 36 5 1 extension tube item 34 6 1 coupling item 35 7 1 discharge spout 8 Limited 1 Year Warranty Morse drum handling equipment is guaranteed against defects in workmanship or materials for one year when used properly within its rated capacity Warranty does not cover wear from normal use or damage from accident or abuse Motors and ot...

Page 2: ...UTION DO NOT allow drum to impact on floor ground or dumping station etc WARNING Verify the chemical compatibility of the materials of your pump with the liquid you want to pump If you are uncertain regarding chemical compatibility contact your dealer for applications assistance and request a copy of our Corrosion Resistance Charts Do not use a pump that is not chemically compatible with the liqui...

Page 3: ...E ONLY ORIGINAL FACTORY REPLACEMENT PARTS B When pumping flammable liquids ensure adequate ventilation C to prevent explosive build up of fumes Pumping should always be done in a NO SMOKING area Approved fire extinguishers in good condition should be available for fire suppression Containers holding flammable liquids should be grounded and D portable containers bonded to prevent explosion hazards from...

Page 4: ...alled between the hairpin clip and the link CAUTION This hole is used for security lock only 6 Remove hose from hanger and place nozzle in container G Operate handle to prime the pump 3 6 strokes are required under most conditions After the pump is primed it will deliver about one gallon for every four full strokes backward and forward Two Position Pump Handle Trouble Shooting Guide A pump will no...

Page 5: ...acing each other when installed The discharge valve seats upper two should have b springs facing away from each other Install piston rod O ring item 11 Install retainer plate item 2 10 with the groove facing AWAY from the pump housing Ensure piston item 28 has O ring item 29 and teflon ring item 30 installed Teflon ring will stretch enough to install by hand tools may damage the piston Slide piston ...

Page 6: ...ectrical interconnection between containers such as a drum and a receiving can Bonding must be completed BEFORE pumping begins See diagrams below GROUNDING is the electrical connection between a container and a constant ground A constant ground would be a metal pipe or rod in contact with the earth An underground tank and piping connected to it would be inherently grounded by nature of the install...

Page 7: ...ir Kit Description 26 5867 P Cork Nitrile Gasket Viton O Rings Polyester Valves Teflon Piston Ring 27 1AE 5869 P EPDM Gasket and O Rings Polyester Valves Teflon Piston Ring 27 4AV 5866 P Viton Gasket and O Rings Polyester Valves Teflon Piston Ring 28 5BV 5865 P Viton Gasket and O Rings Halar Valves Teflon Piston Ring 28 6BE 5868 P EPDM Gasket and O Rings Halar Valves Teflon Piston Ring ...

Page 8: ... SCREW 1 4 20 X 2 SS PAC 21 1 26 27 1AE 27 4AV 1214 30 ADAPTER HOSE PE 60DEG PAC 21 1 28 5BV 28 6BE 1214 90 ADAPTER HOSE HALAR 60DEG PAC 22 11 26 27 1AE 27 4AV 0721 00 NUT 1 4 20 HEX PLATED PAC ITEM QTY MODEL PART DESCRIPTION 22 11 28 5BV 28 6BE 0721 10 NUT 1 4 20 HEX SS PAC 23 2 27 1AE 1340 02 VALVE ASM SMALL PE EPDM PAC 23 2 26 27 4AV 28 5BV 1340 03 VALVE ASM SMALL PE VITON PAC 23 2 28 6BE 1340 ...