morse 26 Operator'S Manual Download Page 1

Copyright 2019  -  Morse Mfg. Co., Inc. 

 

 

Form PL26 

 

(Updated 11 Jun, 2019)

               

1

The Specialist In Drum Handling Equipment

Drum Pumps

[email protected]

103 Kuhn Rd.

Syracuse, NY, 13208 U.S.A.

morsedrum.com

(315) 437-8475

Contents

Page

Receiving Procedures. . . . . . . . . . . . . . . . . . . .   1
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1
Safety Information. . . . . . . . . . . . . . . . . . . . .   1 - 3
Description.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .      3
Operating Instructions. . . . . . . . . . . . . . .. . . . .     4
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . .   5
Handling  Flammable  Liquids.  .  .  .  .  .  .  .  .  .  .  .  .      6
Parts List and Diagram. . . . . . . . . . . . . . . . . .   7 - 8

operator’s Manual 

for Morse Drum Pump Models 

26,  27-1Ae,  27-4AV,  

28-5BV  and  28-6Be

Receiving Procedures

Every Morse drum handler is inspected prior to shipping. However, 

damage may be incurred during transit.

Check for visible damage. If you choose to accept damaged 

• 

freight, always sign noting the damage on the 

Bill of 

Lading

Document the damage and have the truck driver sign. We 

• 

recommend keeping a digital camera at your receiving dock 

for this purpose. 

Open packages expeditiously to check the condition of the 

• 

goods. There is only a 24 hour window to notify the carrier 

of any concealed damage. 

Immediately 

• 

report all damage to the shipping company!

 

Then you may contact Morse for assistance with your 

freight claim. 

Morse Manufacturing will not be held responsible for any 

• 

damaged freight that is not signed for as damaged. 

Depending on model number and options ordered the 

• 

following parts are shipped loose in the carton and should 

be checked before destroying the carton and packaging 

material. See the drawing in page 7 to help identify these 

parts.

1 bung adaptor (item 32)

1. 

1 clamp (item 31)

2. 

1 hose (item 17), complete with: 1 hose adaptor  

3. 

(item 21) 

1 nozzle (item15), 2 hose clamps (item16)

4. 

1 suction tube (item 36)

5. 

1 extension tube (item 34)

6. 

1 coupling (item 35)

7. 

1 discharge spout

8. 

Limited 1 Year Warranty

Morse drum handling equipment is guaranteed against defects in 

workmanship or materials for one year when used properly within 

its rated capacity. Warranty does not cover wear from normal use 

or damage from accident or abuse. Motors and other purchased 

parts carry the warranties of their manufacturers. For warranty 

claims, contact your Morse Dealer to obtain a return authorization 

number, and for return freight advice. Return freight must be 

prepaid.

In all instances, liability is limited to the purchase price paid or to 

repairing or replacing the product. Customer assumes liability for 

any modifications, unauthorized repairs or parts substitution.

safety Information

While Morse Manufacturing Co. drum handling equipment is 

engineered for safety and efficiency, a high degree of responsibility 

must be placed upon the machine operator to follow safe practices, 

based primarily on common sense, upon which true safety 

depends.

Failure to follow the safety precautions in this manual can result in 

personal injury or property damage. Observe the same precautions 

as with similar machinery where carelessness in operating or 

maintenance is hazardous to personnel. Carefully read the safety 

precautions below and throughout this manual.

Review the Material Safety Data Sheet(s) for the material(s) in 

the drum(s) and take all necessary precautions. Safety shoes, 

work gloves, hard hat and other personal protective devices are 

recommended.

Prior to initial use, inspect all moving parts. Inspect pump for 

proper operation. Perform necessary test, inspections, operator 

training, etc.

Summary of Contents for 26

Page 1: ...tem 21 1 nozzle item15 2 hose clamps item16 4 1 suction tube item 36 5 1 extension tube item 34 6 1 coupling item 35 7 1 discharge spout 8 Limited 1 Year Warranty Morse drum handling equipment is guaranteed against defects in workmanship or materials for one year when used properly within its rated capacity Warranty does not cover wear from normal use or damage from accident or abuse Motors and ot...

Page 2: ...UTION DO NOT allow drum to impact on floor ground or dumping station etc WARNING Verify the chemical compatibility of the materials of your pump with the liquid you want to pump If you are uncertain regarding chemical compatibility contact your dealer for applications assistance and request a copy of our Corrosion Resistance Charts Do not use a pump that is not chemically compatible with the liqui...

Page 3: ...E ONLY ORIGINAL FACTORY REPLACEMENT PARTS B When pumping flammable liquids ensure adequate ventilation C to prevent explosive build up of fumes Pumping should always be done in a NO SMOKING area Approved fire extinguishers in good condition should be available for fire suppression Containers holding flammable liquids should be grounded and D portable containers bonded to prevent explosion hazards from...

Page 4: ...alled between the hairpin clip and the link CAUTION This hole is used for security lock only 6 Remove hose from hanger and place nozzle in container G Operate handle to prime the pump 3 6 strokes are required under most conditions After the pump is primed it will deliver about one gallon for every four full strokes backward and forward Two Position Pump Handle Trouble Shooting Guide A pump will no...

Page 5: ...acing each other when installed The discharge valve seats upper two should have b springs facing away from each other Install piston rod O ring item 11 Install retainer plate item 2 10 with the groove facing AWAY from the pump housing Ensure piston item 28 has O ring item 29 and teflon ring item 30 installed Teflon ring will stretch enough to install by hand tools may damage the piston Slide piston ...

Page 6: ...ectrical interconnection between containers such as a drum and a receiving can Bonding must be completed BEFORE pumping begins See diagrams below GROUNDING is the electrical connection between a container and a constant ground A constant ground would be a metal pipe or rod in contact with the earth An underground tank and piping connected to it would be inherently grounded by nature of the install...

Page 7: ...ir Kit Description 26 5867 P Cork Nitrile Gasket Viton O Rings Polyester Valves Teflon Piston Ring 27 1AE 5869 P EPDM Gasket and O Rings Polyester Valves Teflon Piston Ring 27 4AV 5866 P Viton Gasket and O Rings Polyester Valves Teflon Piston Ring 28 5BV 5865 P Viton Gasket and O Rings Halar Valves Teflon Piston Ring 28 6BE 5868 P EPDM Gasket and O Rings Halar Valves Teflon Piston Ring ...

Page 8: ... SCREW 1 4 20 X 2 SS PAC 21 1 26 27 1AE 27 4AV 1214 30 ADAPTER HOSE PE 60DEG PAC 21 1 28 5BV 28 6BE 1214 90 ADAPTER HOSE HALAR 60DEG PAC 22 11 26 27 1AE 27 4AV 0721 00 NUT 1 4 20 HEX PLATED PAC ITEM QTY MODEL PART DESCRIPTION 22 11 28 5BV 28 6BE 0721 10 NUT 1 4 20 HEX SS PAC 23 2 27 1AE 1340 02 VALVE ASM SMALL PE EPDM PAC 23 2 26 27 4AV 28 5BV 1340 03 VALVE ASM SMALL PE VITON PAC 23 2 28 6BE 1340 ...

Reviews: