Morris MDE20291 User Manual Download Page 1

Summary of Contents for MDE20291

Page 1: ......

Page 2: ...Drainage 11 Care and Maintenance 11 Troubleshooting 13 This product is using the Environment friendly refrigerant R290 ODP value is 0 GWP value is 3 3 this refrigerant is tasteless and combustrible m...

Page 3: ...een given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by sprayi...

Page 4: ...r industrial environment where air composition is flammable Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills Do not operate and follow...

Page 5: ...ogic MORRIS dehumidifiers feature an intelligent humidistat which is adjustable in increments of 5 from 40 80 RH insuring your room is not dried too much and power is not wasted Features Your dehumidi...

Page 6: ...PARTS 5 GENRERAL DESCRIPTION 9 Filter 12 Power cord 11 Back cover 10 Continuous drain port 8 Water tank 7 Air inlet 6 Handle 5 Wheel 4 Lamp 3 Air outlet 2 Control panel 1 Oscillation louver...

Page 7: ......

Page 8: ...e a Delayed power on function the appliance is in stand by status USE key UP and DOWN to set the time period 1 24 hours The appliance will start once time reaches set value b Delayed power off functio...

Page 9: ...speed High Fan Mode The fan will move the air around the room ensuring the entire air in the room is processed and the relative humidity correctly measured This mode gives you the ability to adjust th...

Page 10: ...ion The water level control switch shuts off the dehumidifier when the tank is full or when the tank is removed or not replaced in the proper position Empty and replace to resume operation Auto Defros...

Page 11: ...area you can begin by positioning the dehumidifier there and moving it to a more central location at a later date For the most effective use run your dehumidifier with external doors and windows kept...

Page 12: ...water pump e g when draining a cellar to lift the water upwards Care and Maintenance Always shut off the unit and unplug from the mains before cleaning or performing any maintenance When it is not in...

Page 13: ...e special cord storage rest at the back of the unit 4 Cover the unit and keep it in a dry place Frequently Asked Questions Why doesn t the dehumidifier seem to extract much water if the temperature is...

Page 14: ...obstructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit...

Page 15: ...e refrigerant is present Pre operation and during operation should be monitored in the area using an appropriate refrigerant monitor to ensure that the technicians are aware of the presence of potenti...

Page 16: ...erformed on the most dangerous parts to prevent potential dangerous situations from occurring B 2 In the following maintenance of electrical components special care shall be taken not to cause mainten...

Page 17: ...with inert gas cutting pipelines or welding Refrigerant should be recycled to a suitable storage tank The system should be purged with oxygen free nitrogen to ensure safety This process may need to b...

Page 18: ...to be removed during maintenance or scrap It is recommended that the refrigerant be completely removed When loading the refrigerant into the tank use only a dedicated refrigerant tank It is necessary...

Page 19: ...uld be disposed of separately from your household waste Please dispose of this equipment at your local community waste collection recycling centre In the European Union there are separate collection s...

Page 20: ......

Reviews: