13
Note:
1. The center pin of BNC should be read on LED 2.
2. As Coaxial cable has only two wires, we suggest you read
the result of the LED scan using Manual mode.
Remote Test
1. Plug one end of the tested cable to the transmitting RJ45
jack on the master unit marked with a ' ' and plug the other
end into the remote terminator. If the tested cable is
installed in a patch panel or wall plate, you may use the
included patch cable to solve the connector gender
problem.
2. Now, set the Auto/Manual switch to Auto mode for
one-person testing.
3. Read the test results from the LED display on remote
terminator.
Note:
The LED display on the remote unit will scan in
sequence corresponding to the transmitting end of the
master unit.
Sample Test Results
1 2 3 4 5 6 7 8 G
1. Continuity: Pin 2 has continuity
1 2 3 4 5 6 7 8 G
2. Open: Pin 2 is opened
1 2 3 4 5 6 7 8 G
3. Short: Pin 2 and Pin 3 are shorted
1 2 3 4 5 6 7 8 G
4. Miswire: Pin 3 and Pin 6 are miswired