11
REPLACING THE BATTERY
1. Remove the bottom cover and secure the screw.
2. Replace old battery with fresh two 1.5V AAA & 9V type
battery.
3. Replace the bottom cover and secure the screw.
REPLACING THE FUSES
WARNING: To avoid electric shock, disconnect the test
leads from any source of voltage before removing the fuse
cover.
1. Disconnect the test leads from the meter.
2. Remove the protective rubber holster.
3. Remove the battery cover (two “B” screws) and the
battery.
4. Remove the four “A” screws securing the rear cover.
5. Lift the center circuit board straight up from the
connectors to gain access to the fuse holders.
6. Gently remove the old fuse and install the new fuse into
the holder.
7. Always use a fuse of the proper size and value
(0.2A/250V fast blow for the 200mA range).
8.
Align the center board with the connectors and gently
press into place.
9.
Replace and secure the rear cover, battery and battery
cover.
Multi-Network Modular Cable Tester Operation
Note:
Make sure the battery power is sufficient. Insufficient
battery power will lead to dimmed LEDs and incorrect
results.