25
TriStar MPPT 600V Operator’s Manual
24
Installation
Use a #2 Phillips screw driver to remove the four (4) screws that secure the wiring box cover as
s o n in fi re
e o
Figure 3-7. Remove the wiring box cover
Step 2 - Remove the Wiring Divider (TS-MPPT-60-600-V48 and TS-MPPT-60-
600V-48-DB) and Solar Terminal Bridge (TS-MPPT-60-600V-48 ONLY)
The wiring divider separates the solar high voltage wiring from the low voltage battery and
communication circuits. See Figure 3-8 . The divider is secured with only one screw.
1. Use a #2 Philips screw driver to remove the screw.
2. Lift and tilt the divider towards the bottom of the unit as shown in Figure 3-8.
3. Lift the divider out of the wiring box and set the divider and screw aside. The divider
must be replaced in a later step.
1
2
3
Figure 3-8. Remove the Wiring Divider
The Solar Terminal Bridge provides a safe path between the Solar power terminals and the
600V high voltage wiring area. The bridge is removable to allow access to the conduit knock-outs
below the bridge. To remove the bridge, gently pull the bridge straight out of the wiring box as
s o n in fi re
Figure 3-9. Remove the Solar Terminal Bridge.