61
M O R N I N G S T A R C O R P O R A T I O N
Appendices
60
T E C H N I C A L S P E C I F I C A T I O N S
I I
BATTERY CHARGING STATUS LEDs
G
13.3 to PWM
G/Y
13.0 to 13.3 V
Y
12.65 to 13.0 V
Y/R
12.0 to 12.65 V
R
0 to 12.0 V
Note: Multiply x 2 for 24V systems, x 4 for 48V systems
Note: The LED indications are for charging a battery. When discharging, the
LEDs will typically be Y/R or R.
MECHANICAL
• Dimensions (mm/inch)
H: 260.4 mm / 10.25 inch
W: 127.0 mm / 5.0 inch
D: 71.0 mm / 2.8 inch
• Weight (kg/lb)
1.6 kg / 3.5 lb
• Power terminals:
compression connector lug
largest wire
35 mm
2
/ 2 AWG
smallest wire
2.5 mm
2
/ 14 AWG
• Terminal wire slot
8.2 mm / 0.324 in wide
9.4 mm / 0.37 in high
• Knockout sizes
1 and 1.25 inch
• Torque terminals
5.65 Nm / 50 in-lb
• RTS / Sense terminals:
wire sizes
1.0 to 0.25 mm
2
/ 16 to 24 AWG
torque
0.40 Nm / 3.5 in-lb
ENVIRONMENTAL
•
Operating Altitude Below 2000 meters
• Ambient temperature
–40 to +45ºC
• Storage temperature
–55 to +85ºC
• Humidity
100% (NC)
• Enclosure
IP20 Type 1 (indoor & vented),
powder coated steel
Appendix 1 — Load & Lighting Control DIP Settings
The
NOTE
: The DIP switches should be changed only when there is no power to
the controller. Turn off disconnect switches and remove power to the
controller before changing a DIP switch. A fault will be indicated if a switch is
changed with the controller powered.
REMARQUE
: Les commutateurs DIP ne doivent être changés que si le
contrôleur est hors tension. Mettez les interrupteurs sur arrêt et mettez le
contrôleur hors tension avant de changer un commutateur DIP. Une panne
sera indiquée en cas de changement d’un commutateur quand le contrôleur
est sous tension.
CAUTION
: The TriStar is shipped with all the switches in the “OFF” position.
Each switch position must be confirmed during installation.
An incorrect setting could cause damage to the load or other system
components.
PRUDENCE
: Le TriStar est expédié avec tous les interrupteurs en position
« ARRÊT ». La position de chaque interrupteur doit être confirmée pendant
l’installation. Un mauvais réglage peut endommager la charge ou d’autres
composants du système.
Figure A1-1 - Step 3. Load / lighting DIP Switch Functions
Control Mode/
DC Load Control (1)
System Voltage (2,3)
LVD/LVD
R
(4,5,6
)
Not Used (7)
Off - Load Control (8)
On - Lighting control (8)
1
2
3
4
5
6
7
8
DIP
ON
ON
OFF