![Morningstar TriStar MPPT Series Installation, Operation And Maintenance Manual Download Page 30](http://html1.mh-extra.com/html/morningstar/tristar-mppt-series/tristar-mppt-series_installation-operation-and-maintenance-manual_1834373030.webp)
58
Networking and Communication
Email & SMS Alerts
7KHHPDLODQG606DOHUWVIHDWXUHVHQGVQRWL¿FDWLRQWRDQHPDLODGGUHVVRUPRELOHSKRQHLIRQH
of the following occurs:
• TriStar MPPT 150V self diagnostics fault condition
• TriStar MPPT 150V self diagnostics alarm condition
•
8VHUGH¿QHGHYHQWHJEDWWHU\YROWDJHLVOHVVWKDQ9ROWV
8SWRIRXUHPDLODQG606DOHUWVFDQEHFRQ¿JXUHGIURPWKHQHWZRUNVHWWLQJVZHESDJHLQWKH
MSView TriStar MPPT 150V wizard.
View Logged Data
The TriStar MPPT 150V logs up to 200 days* of daily data. The controller always logs the stan-
GDUGYDOXHVOLVWHGEHORZ8VLQJ069LHZWKHFRQWUROOHUFDQEHFRQ¿JXUHGWRORJDGGLWLRQDORSWLRQ
-
al values each day. The maximum number of days that can be stored decreases as the number
of logged values increases.
Standard Values
• Minimum Battery Voltage
• Maximum Battery Voltage
• Daily Events (Equalize triggered, Entered Float, Alarm/Fault occurred, Controller Reset)
• Faults / Alarms - recorded only if a fault or alarm occurs that day
Optional Values
• Maximum Array Voltage
• Maximum Power Output
• Charge Amp-hours
• Charge Watt-hours
• Minimum/Maximum Battery Temperature
• Charge stage regulation timers for Absorption, Float, Equalize
* logging only standard values
SNMP
For telecom and industrial applications that require SNMP monitoring of deployed systems, the
TriStar MPPT 150V will behave as an SNMP agent and supports the following commands:
TRAP
GET
GETNEXT
A link to the agent
Management Information Base
¿OH0,%LVDYDLODEOHRQWKH
TriStar MPPT 150V Live View
Network Settings
page.