background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

December 2015 Version 2.2 

98/37/EC  
89/336/EEC  
73/23/EEC 
93/42/EEC

 

 

 

 

Manual Covers Models: 

BASIC-ONE

 

  CSA - UL 

 

 
 
 

BASIC-ONE

 

Maintenance ~ Service Manual 

Summary of Contents for MEDesign BASIC-ONE CSA-UL

Page 1: ...December 2015 Version 2 2 98 37 EC 89 336 EEC 73 23 EEC 93 42 EEC Manual Covers Models BASIC ONE CSA UL BASIC ONE Maintenance Service Manual ...

Page 2: ...attention The procedure should only take a small amount of time and is quite straight forward During the maintenance procedure take care to detach the table from the mains power supply whilst cleaning and re attach the table for the portions of the procedure that involve table movements Do not access any the internal cavities of any control box or electrical assembly Do not reach under the table t...

Page 3: ...s ordered from the manufacturer 9 Using a commercial vinyl cleaner and or preservative clean and cosmetic the vinyl top Use the cleaner on all exposed sides insuring that all elements of grease and grime are removed Take care to include seams and cracks sides and every surface that can be reached by a cloth held in the hand 10 Wipe down the power cord using a damp cloth or sponge Let dry 11 Reconn...

Page 4: ...art below or make a copy to keep with your table It is the responsibility of the user to have annual inspections and cleaning of the table to continue the validation of the warranty This process includes a visual inspection of all moving components and joints and the cleaning of all patient contact surfaces Examine the soft control tubes leading to the hand controller for kinks or cracks Insure th...

Page 5: ...air is at the risk of the instigator and Morgan MEDesign Inc holds it self clear and harmless for actions that result during and after such procedures 4 All removed attachments must be placed back into their original positions Careful mechanical detailing and matching of tolerance parts have resulted in mandated placements that must remain after the procedure 5 All safety labels must remain in pla...

Page 6: ...y be due to wiring inside the base assembly This may been in the FILTER or at the terminal strips Gain access to the inner BASE wiring and refer to the SCHEMATIC Establish where power loss occurs CHECK KOM POWER CORD Remove cord from KOM BOX at connector and use volt meter to validate AC volts on plug AC ABSENT BASE wiring of KOM POWER CORD is faulted or terminal strip connection fault AC THERE Po...

Page 7: ...tion refer to the OPERATION MANUAL MONITOR CIRCUITS are O K FILTER is O K FAIRCHILD MONITOR is O K LINE VOLTAGE is O K 12 VOLT SUPPLY is O K POSSIBLE OVERHEATED MOTOR The motor drives have a duty cycle and when this is exceeded will self protect with a thermal electrical breaker WAIT 10 MINUTES and TRY OPERATION AGAIN Possible KOM BOX failure or HAND CONTROLLER failure or HAND CONTROLLER CABLE fai...

Page 8: ... voltage AC O K Possible wiring fault in the BASE This may also indicate a failed RENTEC or FAIRCHILD monitoring module Replacement of the MONITOR STRIP may be necessary the assembly that carries both of these modules Gain access to the BASE wiring Check all wires to and from the RENTEC and FAIRCHILD monitors to be secure Morgan MEDesign Inc Maintenance Service Manual BASIC ONE 2005 Page 7 Gain ac...

Page 9: ...e MOTOR OVERHEATED NO YES WEIGHT TOO GREAT NO Check limits All MOTOR mechanical connections secure and in place YES Morgan MEDesign Inc Maintenance Service Manual BASIC ONE 2005 Page 8 POSSIBLE OVERHEATED MOTOR The motor drives have a duty cycle and when this is exceeded will self protect with a thermal electrical breaker WAIT 10 MINUTES and TRY OPERATION AGAIN WAIT 10 MINUTES MORE if NO OPERATION...

Page 10: ...ocedure Table AV PB LARGE ASSY LARGE PILLOW BLOCK 1 000 ASSEMBLY JAR CAS 5 50 LOCKING CASTER LOCKING 5 50MG213GD 4 000 APSL FGOALP025213GDD MAG EHA1321B3ON 000 6 Button Hand Control Wired 1 000 with holder DC MAG KOM14020A 000 KOM BOX KOM14 020A 000 1 000 LG BOX WITH CORD 140360 HOSPITAL CORD MAG MAX10C100 MAX10 C100295A0A1MO 000 1 000 DC TILT 100mm stroke LAT 1500N MAG POWER CABLE DB 9 Cable DB 9...

Page 11: ...Y 1 000 MMI20044 TREN LAT BR TREN LAT BRACKET ASSY 1 000 GASKET 20045 MOTOR GASKET 20045 1 000 1 16 ABS PLASTIC GASKET 7 75 X 7 75 W 4 HOLES MMI20047 1 RISER 1 RISER BLOCK 1 000 5 75 X 5 75 X 1 MCM 9688K281 PLUG NYLON SNAP IN UNVENTE 2 000 13 16 ID X 1 1 32 HEAD MAG MAX30A12335 CURL MAX30A120335AOA1 00 000 1 000 DC Tilt Motor 8000N CURLY CORD 120mm stroke TREND WASHERS 20046 2 1 4 X 1 0 X 3 75 6 0...

Page 12: ...RGENCY SWITCH HARNESS for BASIC NE 1 000 E 20048 7 KOM CORD HARNESS for BASIC ONE 1 000 E ALLIED315 0009 EMERGENCY SWITCH ACTUATOR with CLAMP 1 000 E ALLIED677 0156 CIRCUIT BREAKER 16 amp 1 000 E HS1138LIQTIGHT LIQUID TIGHT LPT 3 8 NPT Grey Pass through 2 000 CSA MANUAL BASIC OPERATING OPERATION MANUAL BASIC ONE 1 000 CSA MANUAL BASIC MAIN SERVICE SERVICE MANUAL BASIC ONE 1 000 E ALLIED937 9615 BU...

Page 13: ...BASIC ONE PICTORIAL PARTS IDENTIFICATION DIAGRAM This diagram depicts parts common to both UL and CSA CE versions of this equipment Morgan MEDesign Inc Maintenance Service Manual BASIC ONE 2005 Page 12 ...

Page 14: ...Morgan MEDesign Inc Maintenance Service Manual BASIC ONE 2005 Page 13 SCHEMATICS FOR BASIC ONE FOLLOW NEXT 4 PAGES If more detail is necessary contact Morgan MEDesign Inc ...

Page 15: ...OWER CONTROLLER LEGEND W WHITE WIRES NEUTRAL COMMON B BLACK WIRES HOT ACTIVE PHASE G GREEN AND GROUND WIRES BLOCK DIAGRAM CHASSIS CONNECTION G B W W B HOLE IN LID OF BASE HOLE IN LID OF BASE B W G WITHIN BASE LIFT MOTOR TREND MOTOR R L TILT MOTOR AC CONTROL 1 2 3 KOM CONTROLLER IN OUT OUT IN TYPES OF KOM CONTROL UNITS KOM 14 020A 000 5 PORT 3 PORTS USED KOM 33 020A 000 3 PORT ALL PORTS USED W B HO...

Page 16: ...R CONTROLLER LEGEND W WHITE WIRES NEUTRAL COMMON B BLACK WIRES HOT ACTIVE PHASE G GREEN AND GROUND WIRES BLOCK DIAGRAM CHASSIS CONNECTION G B W W B HOLE IN LID OF BASE HOLE IN LID OF BASE B W G WITHIN BASE LIFT MOTOR TREND MOTOR R L TILT MOTOR AC CONTROL 1 2 3 KOM CONTROLLER IN OUT OUT IN TYPES OF KOM CONTROL UNITS 220 V KOM 14 020A 000 5 PORT 3 PORTS USED KOM 33 020A 000 3 PORT ALL PORTS USED W B...

Page 17: ... OF KOM CONTROL UNITS KOM 14 020A 000 5 PORT 3 PORTS USED KOM 33 020A 000 3 PORT ALL PORTS USED EMERGENCY STOP SWITCH LINE FILTER CORCOM 50 60 HZ 15EHT1 B B G W W ALARM TROUBLE POWER AUDIO ALARM RENTEC STATUS MONITOR POW POW TROB TROB ALRM ALRM BP BP V NH OK NL OK NS1 OK NS2 OK OV LINE NEUT SENS1 SENS2 0V 12V 12 POWER SUPPLY 2 AMP UL LISTED CSA CE 1 2 3 4 5 6 3 4 5 6 7 8 1 2 3 4 5 6 8 10 2 1 VERSI...

Page 18: ... KOM CONTROL UNITS 220 V KOM 14 020A 000 5 PORT 3 PORTS USED KOM 33 020A 000 3 PORT ALL PORTS USED EMERGENCY STOP SWITCH LINE FILTER CORCOM 50 60 HZ 15EHT1 B B G W W ALARM TROUBLE POWER AUDIO ALARM RENTEC STATUS MONITOR POW POW TROB TROB ALRM ALRM BP BP V NH OK NL OK NS1 OK NS2 OK OV LINE NEUT SENS1 SENS2 0V 12V 12 POWER SUPPLY 2 AMP UL LISTED CSA CE 1 2 3 4 5 6 3 4 5 6 7 8 1 2 3 4 5 6 8 10 2 1 VE...

Reviews: