Auto Inclusion 

The function of auto inclusion will be executed as long as the meter does not 
have Node ID and just connect the meter to main power. When first power is applied, 
its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It 
implies that it is in leaning mode now. 

Note: Auto inclusion timeout is 2 minute during which the node information of explore 
frame will be emitted once every 5 seconds.    Unlike “inclusion” function as shown in 
the table below, the execution of auto inclusion is free from pressing the Include 
button on the meter. 

The table below lists an operation summary of basic Z-Wave functions. Please refer 
to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to include/exclude/associate devices

 

Function 

Description 

LED Indication 

No node ID 

The Z-Wave Controller does not allocate 
a node ID to the meter. 

LED 2-second on, 2-second 
off 

Inclusion 

1. Put your Z-Wave controller into
inclusion mode by following the   
instructions provided by the controller 
manufacturer. 

One press one flash LED 

2. Pressing Include button three times
within 2 seconds will enter inclusion 
mode. 

Exclusion 

1. Put your Z-Wave controller into
exclusion mode by following the 
instructions provided by the controller 
manufacturer.   

One press one flash LED 

2. Pressing Include button three times
within 2 seconds will enter exclusion 
mode. 

3. Node ID has been excluded.

LED 0.5s On, 0.5s Off   
(Enter auto inclusion)   

Reset 

1.

Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.

Use this procedure only in 
the event that the primary 
controller is lost or otherwise 

2.

Within 1 second, press Include
button again for 5 seconds.

inoperable. 

3.

IDs are excluded.

LED 0.5s On, 0.5s Off   
(Enter auto inclusion)   

Association 

1. The 

iZ2EM

 is an always listening Z- 

        Wave device, so associations be 

added or removed by a controller at 

   any time.  

Or   If your controller requires to have 

the 

iZ2EM

 send a 'node information  

frame' or NIF for associations,  
pressing the On/Off button three times 
within 2 seconds will cause the 

iZ2EM

 

to send its NIF.  

LED One press one flash 

2.

There are 3 groups for the meter

Adding a node ID allocated by Z-Wave Controller means inclusion.    Removing a node

ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave

Controller. 

LED Indication

 

To distinguish what mode the meter is in, view from the LED for identification. 

State Type 
No node ID 

Learning 

LED Indication 
Under normal operation, when the meter has not been allocated a 
node ID, the LED flashes on and off alternately at 2 seconds 
intervals.  
When 

iZ2EM

 is in learning mode, LED flashes on and off alternately 

and repeatedly at 0.5 second intervals.

 

Choosing a Suitable Location 

1.

Do not locate the meter facing direct sunlight, humid or dusty place.

2.

The suitable ambient temperature for the Switch is 0°C~40°C.

3.

Do not locate the meter where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.

4.

After putting it into use, the body of meter will become a little bit hot of which
phenomenon is normal.

www.mordomus.com

Summary of Contents for iZ2EM

Page 1: ... the network Mini size design let the module can easily hide itself into the electricity distribution box and that will be good for the house decoration This dual meter module is able to detect Instant power wattage 13800W 230Vac 60 Amperes of connected light or appliances Adding to Z WaveTM Network In the front casing there is an on off button with LED indicator below which is used to carry out i...

Page 2: ...ressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode Use this procedure only in the event that the primary controller is lost or otherwise 2 Within 1 second press Include button again for 5 seconds inoperable 3 IDs are excluded LED 0 5s On 0 5s Off Enter auto inclusion Association 1 The iZ2EM is an always listening Z Wave device so associations be added or removed by a con...

Page 3: ... up the meter and send it for repair The meter cannot report to the group 1 Not carry out association 2 Same frequency interference 1 Carry out association 2 Wait for a while to re try Specification Operating Voltage Rated Primary Current Range Operating Temperature Frequency Range 100 240VAC 0 05A 60A x 2 Channel Split Core Transformer Minimum 40 m in door 100m outdoor line of sight 0 C 40 C iZ2E...

Page 4: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...

Reviews: