F0

Failed to measure hot
water temperature.

Not LOCKED OUT

F1

1st ignition failure.
The burner is not
ignited.

LOCK OUT

Activation of the
combustion product
discharge control
device (air pressure
switch). 

LOCK OUT

Failure during
operation.The burner
switchs off. Try to
reignite the
appliance.

LOCK OUT

TTB jumper

connector is missing

When ON/OFF button is pressed green
LED does not light

Green LED is lighting but heater does
not work

F2

F3

F4

Check heater is plugged pro-
perly to the mains. Blown fuse in
the power circuit.Blown fuse in
the plug.

Check wiring connections bet-
ween power circuit and electro-
nic circuit.Defective electronic
circuit.

10

USER

6.-  TROUBLESHOOTING  &  FAULT  CODES

Code

Description

Cause

Solution

Fault in the NTC sensor or
defect in wiring.

Call to technical service.
Check the NTC and the wiring

Gas tap closed.

Open the gas tap.

Gas bottle empty.

Replace the gas bottle.

Air in the gas circuit.

Repeat the ignition operation until
appliance ignites.

Wiring in disrepair or improperly
connected.

Repeat the ignition operation.
Check the wiring, the electronic cir-
cuit, the servo valve and electrodes.
If the fault persists call to the technical
sevice and replace the defective
component.

Check pressure switch and wiring.
Review the exhaust fumes outlet. 
If the fault persists, contact technical
service.

Repeat the ignition operation.
Check the wiring, the electronic
circuit, the servo valve and
electrodes.
If the fault persists call to the technical
sevice and replace the defective
component.

Connect the jumper. 
Check the wiring and connections.

Connect the heater.
Replace the blown fuse. 
If the fault persists, contact technical
service.

Connect the wirings properly.
Replace electronic circuit.If the fault
persists, contact technical service.

Electronic circuit fault.
Servo Valve fault.
Ionization electrode fault.

Exhaust fumes outlet blocked.

Gas bottle empty.
Wiring in disrepair or improperly
connected.

Electronic circuit fault.
Servo Valve fault.

Ionization electrode fault.

Lack of the jumper.Wiring in dis-
repair or improperly connected. 

Combustion product discharge
control device (air pressure
switch) or defective wiring.

spark fault

1-10.010.649-ingles:1-10.005.856-ingles  24/03/14  17:41  Página 10

Summary of Contents for F-11 EL

Page 1: ...INSTALLATION AND USERS MANUAL F 11 E L SUPER COMPACT ROOM SEALED WATER HEATER 10 010 649 00 1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 41 Página 1 ...

Page 2: ...1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 41 Página 2 ...

Page 3: ...NTI GEL 27 6 ELIMINATION DES PANNES ET CODES DE PANNES 28 INSTRUCTIONS TECHNIQUES 7 DESCRIPTION DE L APPAREIL 29 8 CARACTÉRISTIQUES TECHNIQUES 31 9 SCHÉMA FONCTIONNEL 32 10 SCHÉMA ÉLECTRIQUE 33 11 COTES D ENCOMBREMENT 34 12 CRITÈRES GÉNÉRAUX D INSTALLATION 35 13 INSTRUCTIONS D INSTALLATION 37 14 INSTRUCTIONS DE MISE EN SERVICE 40 NEDERLANS ALGEMENE VEILIGHEIDSINSTRUCTIES 41 GEBRUIKERS INSTRUCTIES ...

Page 4: ...1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 41 Página 4 ...

Page 5: ...uction concerning the safe use of the appliance by a suitable person responsable for their safety Children must be supervised to ensure that they do not play with the appliance Chlidren must never carry out cleaning and maintenance of the applian ce without adult supervision Make sure that the hooks are correctly installed in the wall in order to ensure the correct hanging and fixing of the applia...

Page 6: ...evices and the instructions for use To start up the water heater it must firstly be connected to the mains using the plug for this purpose Ensure gas and water supplies are connected Ensure the electricity supply is switched on 3 OPERATION Obtaining hot water To start up the heater depress the ON OFF button 3 The heater will then be ready to function automatically when any of the hot water taps ar...

Page 7: ...e presence of air in the gas pipes If this happens the heater will LOCK OUT and a fault code will show in the display Occasionally the heater may fail to ignite due to excessively windy conditions or other adverse atmospheric conditions causing LOCKOUT Insufficient gas pressure faulty regulator or fluctuations in voltage may also cause LOCKOUT and a fault code will show in the display To RESET the...

Page 8: ...he bars with a soft brush or compressed air Do not use chemical products Remove the ignition and ionisation spark electrodes and clean the ends The electrode unit should be replaced every three years Cleaning the heat exchanger Clean the heat exchanger with hot water If it is particularly dirty leave it to soak in hot soapy water Replace the heat exchanger seals when it is refitted Cleaning the co...

Page 9: ...ocks on the installation Please refer to your caravan owner s handbook for the location of all drain cocks Disconnect the mains water inlet stopcock from the caravan pipework this will stop water refilling the pipework if the stopcock fails due to frost damage Protect drain cocks and any open ended pipe from insects or debris To turn the water on again close all drain cocks reconnect and open the ...

Page 10: ...nected Repeat the ignition operation Check the wiring the electronic cir cuit the servo valve and electrodes If the fault persists call to the technical sevice and replace the defective component Check pressure switch and wiring Review the exhaust fumes outlet If the fault persists contact technical service Repeat the ignition operation Check the wiring the electronic circuit the servo valve and e...

Page 11: ...om the outside and the removal of combus tion products to the outside enables it to function totally independently of the room in which it is installed For this reason it is ideally suited for use in leisure accommodation vehicles such as caravan holiday homes motor homes and spe cialised vehicles It is also suitable for boats 11 INSTALLER 7 DESCRIPTION OF THE APPLIANCE 11 13 4 6 10 7 2 15 1 9 5 1...

Page 12: ...manual power selection automatic power modulation depending on water flow and progressive burner ignition 9 WATER VALVE equipped with automatic water flow regulator and manual temperature selector 10 POWER SUPPLY AND CONTROL Supplies heater with 1 5 V from a 220 230 VAC mains voltage Supplies fan and controls removal of combustion products via the air pressure switch 11 ELECTRONIC CIRCUIT for igni...

Page 13: ...Butane G30 Hi 12 68 Kwh kg Kg h 1 74 Propane G31 Hi 12 87 Kwh kg Kg h 1 72 2 H 2 E Natural G20 mbar 12 7 Burner pressure at Natural G25 mbar 16 nominal power 3 3B P Butane G30 mbar 27 Propane G31 mbar 33 5 2H 2E Natural G20 m3 h 23 06 Air Flow needed for Natural G25 m3 h 23 37 the combustion 3 3B P Butane G30 kg h 20 19 Propane G31 kg h 20 27 Water data Water flow 50º C l min 2 5 5 25º C l min 3 7...

Page 14: ...r 12 Distributor 13 Main body 14 Electrode unit 15 Supply and fan control circuit 16 Burner 17 Heat exchanger 18 Fan unit 19 Air pressure switch 20 Ignition box and ionisation safety device 21 Micro switch 22 Distributor connector 23 Venturi 24 Sealed chamber 25 Ø 60 100 coaxial output 26 Supply cable 27 Water flow switch 28 NTC 1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 42 Página 14 ...

Page 15: ...vovalve 4 Micro switch 5 Power supply and fanl control circuit 6 Air pressure switch 7 Fan 8 Ionisation electrode 9 Confirmation electrode 10 Spark electrode 11 Power on LED Green 12 Display 13 Water flow switch 14 NTC 1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 42 Página 15 ...

Page 16: ...DIMENSIONS MODEL Weight Dimensions mm kg A B C D E F G H I J L M N O P Q R W X 11 Litre 15 5 330 595 230 247 60 100 25 122 230 8 50 513 50 106 592 75 7 143 125 143 1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 42 Página 16 ...

Page 17: ...l Standards Your particular attention is drawn to the following relevant standards BS 5482 Part 2 Installations in Caravans and Non Permanent Dwellings PD 5482 Part 3 Installations in Boats BSEN 1949 Installation of LPG System for Habitational Purposes in Leisure Accomodation Vehicles BSEN 721 Leisure Accomodation Vehicles Ventilation Requirements BS EN ISO 10239 2008 Small Craft LPG Systems IMPOR...

Page 18: ...uitable terminal guard should be fitted In certain weather conditions the terminal may emit a plume of steam 12 4 MINIMUM CLEARANCES Minimum clearances of 5mm to the front and sides of the heater must be observed However full access from the front in the form of an opening door must be given to allow access to the controls and for servicing 200mm above the top of the heater case is required for th...

Page 19: ...connections supplied separately 13 2 SELECTING THE POSITION Decide where the heater is to be fixed taking into account the installation requirements in section 12 and the dimensions given in section11 13 3 REMOVING THE COVER Remove the gas knobs and the water temperature dial knob Remove the screw holding the cover in place This is on the front of the cover behind the gas knob Take the cover off b...

Page 20: ...re are various other options available including a vertical flue kit and other variations on the horizontal kit Please ask for details Never use a flue kit not specifically approved for use with this appliance The horizontal pipe may be cut down to size to a minimum of 100 mm to suit the installation or extended to a maximum of a straight run of 4 meters Elbows are available but each will reduce t...

Page 21: ...21 INSTALLER If the length of the pipe is 1 metre or less the diaphragm inner Ø 85 mm sup plied in the accessories bag should be fitted 1 10 010 649 ingles 1 10 005 856 ingles 24 03 14 17 42 Página 21 ...

Page 22: ...WATER CIRCUIT Turn on the water supply and check for leaks 14 4 INITIAL OPERATION Operate the heater as per the instructions in section 2 and 3 of this manual 14 5 FINAL CHECKS Re light and test for gas soundness Carry out an operating gas pressure test to ensure maximum potential performance 14 6 USERS INSTRUCTIONS Upon completion of testing the system the installer should Give the instructions t...

Page 23: ...er à l adresse suivante Nos techniciens certifiés sont à votre disposition Voor gedetaillerdere informatie omtrent onderhoud reparatiehandleidingen technische adviezen en product training wordt u verzocht MORCO te bellen Nr 00 44 1482 325456 of met ons contact op te nemene op onderstaand adres Onze gekwalificeerde bij de aangesloten adviseurs staan klaar om u te helpen MORCO PRODUCTS LTD Morco Hou...

Reviews: