Technical specifications

PROFACTOR S.A., all rights reserved. The technical data and the functional product characteristics can be subject
to modifications. The photocopying, the translation, and all other forms of copying of fragments or of the integrlity 
of this user's manual is prohibited.

Dimensions

Unit: mm (milimeters)

MODEL

CA1000

CA2000

TYPE

NO. OF CHANNELS

Professional power amplifier

2

Professional power amplifier

2

RMS POWER @ 8 , 1kHz, 0.1% T.H.D.

Ω

RMS POWER @ 4 , 1kHz, 0.1% T.H.D.

Ω

RMS POWER @ BRIDGE, 8

Ω

2x 300W

2x 750W

2x 500W

2x 1000W

1000W

2000W

FREQUENCY RANGE

20Hz - 20kHz

20Hz - 20kHz

T.H.D. (20Hz - 20kHz)

< 0.1% @ 1kHz

< 0.1% @ 1kHz

S/N RATIO

-100dB

-103dB

GAIN

750mV

750mV

22k  / 20K

Ω

Ω

22k  / 20K

Ω

Ω

INPUT SENSITIVITY

CONTROLS

INDICATORS

Main switch (on/off), 2x volume/gain control

Bridge/stereo mode selector, ground/lift selector

Power on: green, Signal: yellow, Clip/protect; Red

INPUTS

Balanced signal inputs

Balanced signal inputs

OUTPUTS

CONNECTORS

PROTECTIONS

OPERATING VOLTAGE

POWER CONSUMPTION

COOLING

for Speaker

for Speaker

Input: 3-pin XLR and Jack ¼’’ sockets, Output: Speakon Nl4 connector

Thermal overload, DC, short circuit, clip limiter

230V AC (factory config.), 50~60Hz

1200VA

2000VA

Continuously speed fan, automatic, 230V AC

DIMENSIONS (WxDxH)

2RU space, 360mm depth

2RU space, 460mm depth

WEIGHT

14Kg

18Kg

484

484

430

430

88

88

Professional power amplifiers

CA1000 & CA2000

INPUT CONFIG.

CHANNEL 1 

(BRIDGE)

CHANNEL 2

CLIP

PROT

0dB

-

0dB

-

BRIDGE

STEREO

POWER ON

CA1000

PROFESSIONAL POWER AMPLIFIER

INPUT CONFIG.

CHANNEL 1 

(BRIDGE)

CHANNEL 2

CLIP

PROT

0dB

-

0dB

-

BRIDGE

STEREO

POWER ON

CA2000

PROFESSIONAL POWER AMPLIFIER

S

U E

F

S

U E

F

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

To prevent 

electrical 

To prevent 

electrical 

INPUT (BRIDGE)

INPUT (BRIDGE)

INPUT

INPUT

+2 -2

+2 -2

+1 -1

+1 -1

BALANCED

BALANCED

UNBALANCED

UNBALANCED

PIN

SIGNAL

PIN

SIGNAL

2

2

1 / 2

1 / 2

3

3

1

1

2

2

3

3

1

1

GND

GND

-

-

+

+

GND

GND

+

+

3

3

1

1

2

2

INPUT

INPUT

OUTPUT

OUTPUT

CHANNEL 1

CHANNEL 1

CH1 

SPEAKER

CH1 

SPEAKER

+1 -1

+1 -1

CH2

SPEAKER

CH2

SPEAKER

CHANNEL 2

CHANNEL 2

BRIDGE

BRIDGE

LIFT

LIFT

GND

GND

+1  -1

+1  -1

4 Ohm

4 Ohm

PIN

PIN

SIGNAL

SIGNAL

MIN. LOAD

MIN. LOAD

CHANNEL

CHANNEL

+2  -2

+2  -2

8 Ohm

8 Ohm

BRIDGE

BRIDGE

moosesound.com

moosesound.com

FUSE F         A

FUSE F         A

230V AC
50HZ
             VA

230V AC
50HZ
             VA

PROUDLY 

PROUDLY 

Summary of Contents for CA1000

Page 1: ...RTUGAL Professional power amplifiers CA1000 CA2000 INPUT CONFIG CHANNEL 1 BRIDGE CHANNEL 2 CLIP PROT 0dB 0dB BRIDGE STEREO POWER ON CA1000 PROFESSIONAL POWER AMPLIFIER INPUT CONFIG CHANNEL 1 BRIDGE CHANNEL 2 CLIP PROT 0dB 0dB BRIDGE STEREO POWER ON CA2000 PROFESSIONAL POWER AMPLIFIER ...

Page 2: ...t operating and maintenance instructions The amplifier is marked with this instruction so please proceed accordingly in order to avoid any hazard 1 Before connecting the equipment to the power outlet first verify that the mains voltage and frequency match the values specified on the equipment 2 If the power cord of the device is equipped with an earthing contact then it must be connected to an out...

Page 3: ...can recycle this item in an environmentally friendly manner Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal ENVIRONMENTAL PROTECTION AND ENERGY CONSERVATION Energy conservation is an active contribution to environmental protection Please turn off all unneeded electric...

Page 4: ...ector used to choose between STEREO and BRIDGE Operation Mode In STEREO mode each channel within the pair remains independent and each may be used for a different signal In BRIDGE mode the setting combines both channels of a pair into a single channel with twice the output voltage Use only the input and gain control channel 1 Set the channel 2 gain control at minimum 9 STEREO This LED lights up wh...

Page 5: ... speaker connections 17 BRIDGE Speakon loudspeaker connector to be used if the amplifier is set to be operating in BRIDGE mode Please refer to the pinout printed on the rear panel of the amplifier 18 SIGNAL GROUND LIFT GROUND Signal ground lift barrier strip Ground lift means breaking a connection between chassis earth and electrical earth Use this feature only when 50Hz hum is excisting from loud...

Page 6: ...in XLR and Jack sockets Output Speakon Nl4 connector Thermal overload DC short circuit clip limiter 230V AC factory config 50 60Hz 1200VA 2000VA Continuously speed fan automatic 230V AC DIMENSIONS WxDxH 2RU space 360mm depth 2RU space 460mm depth WEIGHT 14Kg 18Kg 484 484 430 430 88 88 Professional power amplifiers CA1000 CA2000 INPUT CONFIG CHANNEL 1 BRIDGE CHANNEL 2 CLIP PROT 0dB 0dB BRIDGE STERE...

Page 7: ...sesound com PROUDLY DEVELOPED AND MANUFACTURED IN PORTUGAL PROFACTOR S A Rua do Padrão 52 4440 617 Valongo PORTUGAL Telf 351 224 119 160 Fax 351 224 155 822 info profactor pt MOOSE is a brand or PROFACTOR S A ...