Maintenance
B : Seed Distribution
f)
f)
Metering devices
-
Never leave seed for any length of time in the hopper
-
Open shutters (1) and flaps (2) during the storage period
-
Never lubricate or grease metering devices and seed pips
-
Checks – Incorrect setting of flaps (2) may induce oversowing in the course of work.
It is recommended to check and adjust if necessary after each sowing period-
-Set the flap lever to index 1
-Begin with visually assessing the distance between the flap and the peg
wheel
-If necessary, insert a 6mm spacer (3) between the flap and large space peg
wheel.
Adjust the distance with screw (4).