26
27
Rev:5.0
6/08/2010
Rev:5.0
6/08/2010
MSST5/10-S UserManual
MSST5/10-S UserManual
5 Error Codes
Status LED
The ST drives include two (red/green) LEDs to indicate status. Normal status is indicated by a
green LED. If the red LED flashes, an error has occurred. The errors are indicated by combina-
tions of red and green flashes as follows:
Coder
Error
1 red, 2 green
attempted move while drive disabled
2 red, 1 green
CCW limit
2 red, 2 green
CW limit
3 red, 1 green
drive over heating
4 red, 1 green
power supply over voltage
4 red, 2 green
power supply under voltage
5 red, 1 green
over current/short circuit
5 red, 2 green
motor resistance out of range
6 red, 1 green
open motor winding
7 red, 1 green
serial communication error
6 Drive mounting
MSST5/10-S drives can be mounted on the wide or narrow side of the chassis using #6 screws. If
possible, the drive should be securely fastened to a smooth, flat metal surface that will help con-
duct heat away from the chassis. If this is not possible, forced airflow from a fan may be required
to prevent the drive from overheating.
▪ Never use the drive in a space where there is no air flow or where the ambient temperature
exceeds 50ºC (120ºF).
▪ Never put the drive where it can get wet.
▪ Never allow metal or otherwise conductive particles near the drive.