NOTE
With a MSD Single-Axis Servo Drive Compact the temperature
sensor cable can be connected to both X6 and X7.
1)
(MSD Single-Axis Servo Drive Compact and
MSD Servo Drive Safety require an NTC adapter - 220kOhm
available)
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD Servo Drive - Device Help
41
5 Motor
5.5.2 Synchronous motor I²t monitoring
A synchronous motor by design has lower loss than an asynchronous motor,
because permanent magnets replace the magnetizing current. It is normally not
internally cooled, but discharges its heat loss by internal convection. For that reason
a synchronous motor has a different characteristic to an asynchronous motor. It is
necessary to adapt the I
2
t characteristic because the factory setting mostly does not
exactly map the present motor.
Fig. 5.9: “I²T monitoring” screen for a synchronous motor