V1.1.0 RELEASE NOTES

Global Parameters

Group 1

Group Select Key

Parameter Select Key

1.1 Glide Type

F#2

F#0

Grandmother’s Glide type can be changed to best suit playing style or preference. There are three options - Linear Constant 
Rate, Linear Constant Time, and Exponential. To change Grandmother’s Glide Type, press the (

F#2

 + 

F#0

) keys, and then use 

the first three white keys to select LCR (

F0

), LCT (

G0

), or EXP (

A0

). 

The Default is LCR.  

1.2 Gated Glide

F#2

G#0

While Glide is in use, Gated Glide allows Grandmother to transition between the pitch of two notes only when a note is pressed. 
The Glide transition halts in between notes and continues when a new note is pressed. If Gated Glide is off, the transition between 
the pitch of two notes completes in the amount of time set by the 

GLIDE

 knob, regardless of whether or not a note is held. To 

specify the state of Gated Glide, press the (

F#2

 + 

G#0

) keys, and then use the first two white keys to determine if Gated Glide is 

OFF (

FO

), or ON (

G0

). The Default is ON.  

1.3 Transposition Behavior

F#2

A#0

This setting determines how Grandmother will behave when its Octave settings are changed via the Left-Hand Control. To 
specify whether Grandmother’s pitch is transposed Immediately, or when a New Note is played, press the (

F#2

 + 

A#O

) keys, and 

then use the first to white keys to select New Note (

F0

), or Immediate (

G0

). The Default is New Note.  

1.4 Tap-Tempo Clock Division Persistence

F#2

C#1

This setting determines whether the clock divisions specified while Tap Tempo is in use will persist when Tap Tempo is 
disengaged or if the clock divisions will be reset to Eighth Notes when disengaged. Press the (

F#2

 + 

C#1

) keys, and then use the 

first two white keys to determine whether Tap-Tempo Clock Division Persistence is OFF (

F0

), or ON (

G0

). The Default is OFF.   

1.5 Velocity CV Output Range

F#2

D#1

Grandmother’s 

VELOCITY CV

 Output can be set to transmit velocity data at two different voltage ranges. To set the 

VELOCITY 

CV

 Output range, press the (

F#2

 + 

D#1

) keys, and then use the first two white keys to select between -5V to +5V (

FO

), and 0V 

to 10V (

G0

). The Default is -5V to +5V. 

1.6 Oscillator 2 Frequency Knob Range

F#2

F#1

Hold (

F#2

)

 

and press (

F#1

)

 

to select. 0 Semitones / Off (

F0

), 1 Semitone (G0), 2 Semitones (

A0

) … 

7 Semitones (

F1

) is the Default… 18 Semitones (

C3

). Osc 2 Freq Knob Range controls the amount of pitch detuning available 

from the 

FREQUENCY

 knob in the Oscillator 2 section of the front panel. The default is 7 semitones; the range is 0 to 18 

semitones, set using any of the white keys on the keyboard (lowest to highest white key sets range to be 0 to 18 semitones). 

Summary of Contents for Grandmother

Page 1: ...the SysEx file Grandmother_FIRMWARE_ERASE syx included with this download and click Send On the Grandmother the Arp Rate LED will blink red three times then blink green steadily Grandmother is now rea...

Page 2: ...efault External Analog Clock overrides MIDI Sync Added Arp Seq Swing parameter MIDI CC 14 global param ID 22 Added Multi Trig parameter MIDI CC 95 Arp Seq PLAY button does not output MIDI CC 73 can st...

Page 3: ...ng and exit the edit mode NOTE Global Settings are retained even when the power has been turned off For information on advanced Global Settings visit www moogmusic com grandmother HERE S HOW IT WORKS...

Page 4: ...nds To change this setting press the A 0 key and then use the first three white keys to select SEND MIDI CLOCK MIDI START STOP COMMANDS F0 SEND MIDI CLOCK ONLY Don t send MIDI Start Stop commands G0 o...

Page 5: ...4 PPQN C1 5 PPQN D1 6 PPQN E1 7 PPQN F1 8 PPQN G1 9 PPQN A1 10 PPQN B1 11 PPQN C2 12 PPQN D2 24 PPQN E2 48 PPQN The Default is 4 PPQN sixteenth note clock 0 9 KB Out Range none C 2 The voltage range o...

Page 6: ...is transposed Immediately or when a New Note is played press the F 2 A O keys and then use the first to white keys to select New Note F0 or Immediate G0 The Default is New Note 1 4 Tap Tempo Clock Div...

Page 7: ...Arpeggiator or Sequencer is running or to output clock pulses all the time The timing of clock pulses is determined by the tempo in BPM and the Clock Output PPQN setting 1 8 Multi Trig F 2 A 1 F0 off...

Page 8: ...etting controls whether or not MIDI CC messages are output in response to changes made to the front panel controls ON is the setting that allows messages to be sent When MIDI Out Filter Panel Knobs is...

Page 9: ...holding it press the lowest black key F 0 You will see the three buttons on the LHC blink rapidly for a moment to confirm that the reset happened Resetting the global parameters also exits Global Edit...

Page 10: ...tuck in a MIDI feedback loop if these messages are echoed back to the unit TO REQUEST A PARAMETER VALUE F0 04 16 3E Parameter ID 00 00 00 00 00 00 00 00 00 00 Unit ID F7 Values above are shown in hexa...

Page 11: ...efault 1 On 24 Delay Sequence Change 0 Off 1 On Default 0 Off 25 Sequence Latch Restart 0 Off 1 On 26 Arp Seq Clock Input Mode 0 Clock 1 Step Advance Trigger Default 0 Clock 27 Arp Seq Clock Output 0...

Page 12: ...Gated Glide 0 Off 1 On Default 1 On 39 Legato Glide 0 Off 1 On Default 0 Off 40 Osc 2 Freq Knob Range 0 24 Semitones Default 7 41 Osc 2 Hard Sync 0 Off 1 On Default 0 Off 42 Multi Trig 0 Off 1 On Def...