MSD Multi-Axis System Operation Manual DC-AC Servo Drive
89
A Technical data
A.1.3
G393-004 to G393-032 (
air cooling, 480 V AC)
Device
Switching
frequenc
y of the
power stage
Ambient
temperature
Rated current
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C (°F)]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-004 (Size 1)
4
+40
(+104)
5.3
8.4
8.4
10
11.9
0.5
8
3.3
7.0
7.0
-
-
12
2.7
4.8
4.8
-
-
16
1.8
3.4
3.4
-
-
G393-006 (Size 1)
4
+40
(+104)
8.0
12.7
12.7
10
18.0
0.5
8
5.0
10.6
10.6
-
-
12
4.0
7.2
7.2
-
-
16
2.7
5.2
5.2
-
-
G393-008 (Size 2)
4
+40
(+104)
8.5
14.6
14.6
10
21.8
0.5
8
6.1
10.4
10.4
-
-
12
5.4
7.6
7.6
-
-
16
3.9
5.5
5.5
-
-
G393-012 (Size 2)
4
+40
(+104)
11.4
19.5
19.5
10
29.3
0.5
8
9.2
15.8
15.8
-
-
12
8.1
11.4
11.4
-
-
16
5.8
8.2
8.2
-
-
1) At maximum 70 % pre-load
2) Shutdown as per I²t characteristic
All data apply for a motor cable length ≤10 m (32.80 ft)
Table A.3 Rated and peak current, G393-004 to G393-032 (air cooling, 480 V AC)
Device
Switching
fr
equency
of the
power stage
Ambient
temper
atur
e
Rated curr
ent
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C (°F)]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-016 (Size 3)
4
+40
(+104)
20.0
33.6
33.6
10
48.0
0.5
8
13.9
29.1
29.1
-
-
12
8.8
18.9
18.9
-
-
16
6.5
14.8
14.8
-
-
G393-020 (Size 3)
4
+40
(+104)
25.0
42.0
42.0
10
60.0
0.5
8
17.4
36.5
36.5
-
-
12
11.0
23.6
23.6
-
-
16
7.4
16.8
16.8
-
-
G393-024 (Size 4)
4
+40
(+104)
26.0
41.6
41.6
10
62.4
0.5
8
21.0
42.0
42.0
-
-
12
12.4
24.8
24.8
-
-
16
8.9
17.8
17.8
-
-
G393-032 (Size 4)
4
+40
(+104)
33.7
53.9
53.9
10
80.9
0.5
8
28.0
56.0
56.0
-
-
12
16.5
33.0
33.0
-
-
16
11.9
23.8
23.8
-
-
1) At maximum 70 % pre-load
2) Shutdown as per I²t characteristic
All data apply for a motor cable length ≤10 m (32.80 ft)
Table A.2 Rated and peak current, G393-004 to G393-032 (air cooling, 460 V AC)
moog
Id. no.: CA97554-001 0
5