MSD Multi-Axis System Operation Manual DC-AC Servo Drive
59
5 Commissioning
5.4.4
Ethernet IP address menu (IP)
An Ethernet TCP/IP interface is available as a service and diagnostics interface. The IP
address is set in the factory to 192.168.39.5. It can be changed using the PC software
Moog
D
rive
A
DministrAtor
5 or via the
display.
Menu level
Pa-
rame-
ter
Value
range
Meaning
Explanation
1
2
IP
Iu
b0
00..FF
IP address
update byte 0
Setting for byte 0 of the IP address in
hexadecimal format
(e.g. "5" in 192.168.39.
5
)
b1
00..FF
IP address
update byte 1
Setting for byte 1 of the IP address in
hexadecimal format
(e.g. "27" for 192.168.
39
.5)
b2
00..FF
IP address
update byte 2
Setting for byte 2 of the IP address in
hexadecimal format
(e.g. "A8" for 192.
168
.39.5)
b3
00..FF
IP address
update byte 3
Setting for byte 3 of the IP address in
hexadecimal format
(e.g. "C0" at
192
.168.39.5)
Ir
-
-
IP reset to
factory setting
Reset IP address to factory setting
(192.168.39.5)
Su
b0
00..FF
Subnet mask
update byte 0
Setting for byte 0 of the subnet mask in
hexadecimal format
(e.g. "0" in 255.255.255.
0
)
b1
00..FF
Subnet mask
update byte 1
Setting for byte 1 of the subnet mask in
hexadecimal format
(e.g. "FF" in 255.255.
255
.0)
b2
00..FF
Subnet mask
update byte 2
Setting for byte 2 of the subnet mask in
hexadecimal format
(e.g. "FF" in 255.
255
.255.0)
b3
00..FF
Subnet mask
update byte 3
Setting for byte 3 of the subnet mask in
hexadecimal format
(e.g. "FF" in
255
.255.255.0)
Sr
-
-
Subnet mask
reset to
factory setting
Reset subnet mask to factory setting
(255.255.255.0)
Table 5.9 IP address menu
5.4.3
Parameter menu (PA)
The following functions are available on the Parameter menu:
•
Reset device to factory settings
Menu level
Pa-
rame-
ter
Value
range
Meaning
Explanation
1
2
PA
Pr
-
-
Parameter reset
Reset device settings to factory settings.
Table 5.7 Parameter menu
Error messages displayed during user data entry
A failed user action is indicated by an error message. The message consists of the
alternating display of "Er" and the error number.
NOTE:
The error messages displayed during user data entry should not be confused
with drive error messages. You will find detailed information on the er or codes
and on error management in the Device Help.
Error number
Meaning
17
Parameter reset to factory settings failed
18
Parameter write access failed
19
Save parameter data set non volatile failed
20
Not all parameters written
21
Error while reset to factory settings
Table 5.8 Error messages displayed during user data entry
moog
Id. no.: CA97554-001 0
5
/2017