40
MSD Multi-Axis System Operation Manual DC-AC Servo Drive
Figure 4.15 Detail: connection, DC power supply Size 5
Figure 4.16 Detail: connection, DC power supply Size 6A or Size 7 to smaller DC-AC Servo
Drives
4.7 Connection of DC power supply
1.
Make sure all DC-AC Servo Drives are arranged in a row and side by side mounted.
See installation instructions in chapter 3
2.
Use the pre-assembled connection cables supplied for the DC power supply to the DC-AC Servo
Drives. Via the terminals X11 connect together all (+) connections and all (−) connections.
The pre-assembled connection cables supplied are as long as the related device is wide.
3.
You will find more detailed information on the mains connection for the Power Supply Unit in the
Operation Manual MSD Power Supply Unit.
NOTE:
Only use the DC link connections supplied for the electrical coupling of the
devices. If extending the DC link coupling is unavoidable, it is imperative you
pay attention to the requirements in chapter A.5. On the usage of connection
cables that do not meet the requirements, Moog does not provide any
guarantee for stable, safe operation.
NOTE:
Before commissioning, set the value for the supply voltage connected in the
DC-AC Servo Drive.
moog
Id. no.: CA97554-001 0
5
/2017
4 Electrical installation