background image

14 Specifications

Input:

Differential
0 to ±10V
100 kOhm input resistance

Enable:

+10V to +24V
2mA @ 24V 

Outputs:

Dual PWM @ 24kHz
1.0A ±0.1A

Maximum coil resistance:

22 Ohm

Coil current test

0 to –10V for 0 to 1A current

terminals:

Deadband compensation:

±12% nominal, not user adjustable

Dither:

100 Hz
0 to 0.1A

Zero:

0 to ±0.15A

Front panel indicators:

Command – positive = red

negative = green

I(A) = red
I(B) = green

Supply:

24V nominal, 22 to 28V
45mA @ 24V, no load

Mounting:

DIN rail
IP 20

Temperature:

0 to +40ºC

Dimensions:

100W x 108H x 22.5D

Weight:

130g

CE mark:

EN50081.1 emission
EN50082.2 immunity

C tick:

AS4251.1 emission

13 Block-wiring diagram

LED

cmd

+

+

+

+

zero

dither

+24V

+24V

1

2

+24V

+15V

-15V

+

+

A

B

Power Supply

Integrator

Integrator

PWM

PWM

3

5

6

ENABLE

input

Input Amp

Dead Band

Compensation

11

12

9

13

15

16

Coil A

Coil B

test

test

Output A

Output B

LED

LED

7

terminal

terminal

8

4

10

14

+24V

0V

Supply

see note 1

+

0Vref

+

+

Differential

10V

B

B

0 to -10V

0 to -10V

0 to 1Amp

0 to 1Amp

Note:  1. Connect cable screen to enclosure cable gland

 or chassis ground terminal on G123-814.