•  To ensure adequate protective gas flow to the protected enclosure, all piping and tubing must be 

fully reamed.

•  Precaution must be taken to prevent crimping and other damage to protective gas piping and 

tubing.  Caution must be used when opening/closing swing panel to prevent tubing kinks.

•  Supplied 1/4” & 3/8” Poly Tubing have ferrule, nut & insert preset.  Use that end for connecting to 

power box.  Cut other end to attain desired length and connect to push-in fittings on 

Purge/Pressurization Unit.

•  The Tamper-Proof (Primary) Regulator is intended to prevent tampering, while allowing a more 

stable setpoint to be achieved in the small, tightly sealed enclosure where the protective gas flow is 

critically low and difficult to stabilize.  A 5/64” Hex Key or Allen Wrench is required to operate.

•  When performing Initial Purge/Pressurization, adjust Primary Regulator to 5 psi.  Normal operating 

pressure is 2.5 inches of water at Dome Pressure Gauge.  Balance Primary and Secondary 

Regulators for continuous purge by alternately adjusting Primary (5 psi) and Secondary (2.5 inches 

of water).

English

 

SYSTEM MOUNTING

14.7

O  0.32
4 places

PEPPERL FUCHS

+

10.0

3

4

Summary of Contents for EXPDWCN

Page 1: ... camera MPEG 4 MJPEG video compression Full D1 Clear dome with 24VAC input heater blower Analog 7 Explosion Proof PurgeDome Outdoor PTZ Camera Systems for Hazardous environments UL approved for Class 1 Division II applications Includes Purging System and Lines With 23x zoom Day Night camera MPEG 4 MJPEG video compression Full D1 Clear dome with 24VAC input heater blower Before attempting to connec...

Page 2: ...n be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions If technical support or service is needed contact us at ...

Page 3: ... other acts of God i e hurricanes earthquakes failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures recommended by the International Security Industry Organization written in product instructions or recommended in the service manual for the Product Furthermore Videolarm shall have no liability where a sche...

Page 4: ...Content of Box PURGE PRESSURIZATION UNIT SUPPLIED 1 4 3 8 POLY TUBING Content of Box PROTECTED CAMERA ENCLOSURE PAN TILT DOME HARDWARE ...

Page 5: ...urized unit 2 fitting are provided as shown in the diagrams ENCLOSURE SUPPLY OUTLET 3 8 Push in Fitting ENCLOSURE REFERENCE INLET 1 4 Push in Fitting PURGED PRESSURIZATION UNIT ELECTRICAL ALARM WIRING CONDUIT AND SEAL Customer Supplied SYSTEM SUPPLY INLET 3 8 SS Compression Fitting 1 2 ...

Page 6: ...Purge Pressurization Unit The Tamper Proof Primary Regulator is intended to prevent tampering while allowing a more stable setpoint to be achieved in the small tightly sealed enclosure where the protective gas flow is critically low and difficult to stabilize A 5 64 Hex Key or Allen Wrench is required to operate When performing Initial Purge Pressurization adjust Primary Regulator to 5 psi Normal ...

Page 7: ...AMS DOME PRESURE GAUGE ENCLOSURE ATMOSPHERIC REFERENCE EXP PRESURE SWITCH PROTECTED CAMERA ENCLOSURE REFERENCE SYSTEM SUPPLY INLET SUPPLY PRIMARY REGULATOR SECONDARY REGULATOR FLOWMETER TUBING CONNECTION DIAGRAMS ENCLOSURE SUPPLY OUTLET ENCLOSURE REFERENCE INLET SYSTEM SUPPLY INLET PEPPERL FUCHS PURGE PRESSURIZATION UNIT 5 6 ...

Page 8: ...ary SCFH flowmeter is unnecessary Use the permanently installed flowmeter on the swing panel in the Purge Pressurization Unit See supplied Model 1001A Installation and Operation Manual for additional installation and operation information CONNECTION SIZES LENGTHS BENDS System Supply Camera Supply Camera Reference 3 8 OD SS Tubing SUPPLIED SUPPLIED Fully Reamed 3 8 Poly Tubing 1 4 Poly Tubing MAXIM...

Page 9: ...marked on the board and plugged into the corresponding voltage for the input single phase Attach unit securely to the wall mount using 4 3 8 or 8mm hardware not supplied WALL MOUNT The power box may be pole mounted with the pole support clips Stainless steel straps not provided 10 11 12 120Vac Input 240Vac Input Main Switch Connect incoming ground to ground post as shown 13 ...

Page 10: ...igned for 3 phase or 208V systems 24Vac Power To Housing Optional 24Vac Output Main Switch Connect Housing Power Remove Pan Tilt from shipping carton Install in base bracket in housing To secure in place tighten captive screw See S View Pan Tilt instructions for additional details If required the Pan Tilt and dome may be installed before mounting the entire assembly CAPTIVE SCREW 14 15 16 ...

Page 11: ...851200 PAN TILT 2 PR25DCP71000 TRIM RING ASSEMBLY WITH CLEAR DOME To install the dome align the tabs and twist counter clockwise to secure Hand tighten the screws on the dome Recommended torque 12 inches lb 1 35Nm 17 18 Distribuidor Autorizado www segind com br ...

Reviews: