Moog Videolarm WARRIOR 1 Product Instructions Download Page 6

250 ft 

3 4 5 8 

13

300 ft 

4 5 6 

10 

16

400 ft 

5 6 8 

13 

21

500 ft 

6 8 

10 

16 

26

600 ft 

8 10 12 19 31

800 ft 

10 13 16 25 42

1000 ft 

13 16 20 32 52

1250 ft 

16 20 25 40 65

1500 ft 

19 24 30 48 78

1750 ft 

23 28 35 55 91

2000 ft 

26 32 40 63 

104 

2500 ft 

32 40 49 79 

131 

3000 ft 

39 48 59 95 

157 

3500 ft 

45 56 69 

111 

183 

4000 ft 

52 64 79 

127 

209 

5000 ft 

65 80 99 

158 

261 

6000 ft 

78  95 119 190 313 

8000 ft 

104 127 158 253 418 

Unshielded Twisted-Pair Wire Gauge  (AWG)

Cable

Distance

24

22

20

19

18

Unshielded Twisted-Pair Wire Gauge  (AWG)

Distance

24

22

20

19

18

Unshielded Twisted-Pair Wire Gauge  (mm)

Distance

0.5

0.6

0.7

0.8

1.0

3 4 5 8 

13

4 5 6 

10 

17

5 7 8 

13 

21

6 8 

10 

16 

26

9 10 13 21 34

13 16 19 31 51

17 21 26 42 69

21 26 32 52 86

26 31 39 62 

103 

32 39 49 78 

129 

38 47 58 94 

154 

43 52 65 

104 

171 

51 63 78 

125 

206 

64 78 97 

156 

257 

77  94 117 187 309 

102 125 156 249 411 

Cable

Cable

75 m 

100 m

125 m

150 m

200 m

300 m

400 m

500 m

600 m

750 m

900 m

1000 m

1200 m

1500 m

1800 m

2400 m

75 m 

100 m

125 m

150 m

200 m

300 m

400 m

500 m

600 m

750 m

900 m

1000 m

1200 m

1500 m

1800 m

2400 m

3 5 6 9 

13 

4 7 9 

12 

18 

6  8 11 15 22 

7 10 13 18 27 

9 13 17 24 36 

13 20 26 36 54 

18 27 35 48 72 

22 33 43 60 90 

26 40 52 72 

108

33 50 65 89 

135

40 60 78 

107 

162

44 66 86 

119 

179

53 80 

104 

143 

215

66 100 130 179 269

79 120 155 215 323

106 159 207 286 431

0

- 6 -

ADDENDUM 2

IFS FIBER CONNECTION

1.

Connect power to the terminal connector as shown in the general 

     instructions. 

2.

Select a quality fiber optic cable containing either 50/125 or 

     62.5/125 fiber.  Attach an ST style fiber optic connector to the 
     cable using the connector manufacturer's recommended proce-
     dures.  

3.

  Attach the connector just assembled to the ST Connector 

     OPTICAL OUT. Feed the cable through the conduit opening. 
     Complete connections and attach outside the housing according 
     to manufacturer's recommended procedures.

NOTE:

  The customer must purchase the Receiver from IFS.  Part 

             number are:
                       • VR1000

• VR1001

                       • VR1001-R3
                       • VR1100
                       • VR1100-R3
                       • VR2100
                       • VR2100-R3

/LIHWLPHZDUUDQW\RQWKH¿EHUPRGXOH

Figure 20

IFS Fiber Board

ST Connector
OPTICAL OUT

Power board

Summary of Contents for WARRIOR 1

Page 1: ...K XVLQJ D DW KHDG VFUHZGULYHU B Use the 3 4 conduit plug to cover the 3 4 threaded hole To do this loosen the 6 32 set screw that holds the connector in remove the connector and replace it with the pl...

Page 2: ...H VHFWLRQV Use Class 2 Power only Input voltage must be between 12 28 VDC or 15 28 VAC WIRING Figure 3 Connected to the Camera Connect to incoming video BNC Power Board DESCRIPTION The Warrior Test Mo...

Page 3: ...an also be adjusted up and down if needed Retighten the thumb screws 127 8VH RFWLWH RU DQ HTXLYDOHQW SURGXFW WR VHFXUH WKH WKXPE screws especially where vibration is a concern Rotating Bracket CAMERA...

Page 4: ...tch UP DOWN 1 Iris Auto Iris On Position for Fixed Lens 2 Flickerless Shutter speed Normal HG DW VHF 3 Back Light ON Normal Compensation 4 Synch Mode Internal Synch Line Lock Mode SERIAL NUMBERS BEGIN...

Page 5: ...K 6 DO NOT send Up the Coax Pan Tilt Zoom signals through active amplified NVT transceivers Measure your wire distance Note All NVT quoted distance specifications include any coax in the run It is rec...

Page 6: ...000 m 1200 m 1500 m 1800 m 2400 m 75 m 100 m 125 m 150 m 200 m 300 m 400 m 500 m 600 m 750 m 900 m 1000 m 1200 m 1500 m 1800 m 2400 m 3 5 6 9 13 4 7 9 12 18 6 8 11 15 22 7 10 13 18 27 9 13 17 24 36 13...

Page 7: ...appear to be unusually dim STATIONARY OR SCROLLING HORIZONTAL LINES ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the fa...

Page 8: ...k polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at bot...

Page 9: ...4 VAC 202mA 4 8W CABLE AND POWER GUIDELINES This chart shows the proper current needed for power supplies for Warrior Series cameras Use Class 2 Power only Input voltage must be between 12 28 VDC or 1...

Page 10: ...1 2 3 4 5 6 7 10 WS1 Exploded Diagram...

Page 11: ...KIT 486 PAL BOARD CAMERAS RPWS1041PF WARRIOR 1 2 PAL STANDARD RES BLACK WHITE FIXED CAMERA KIT 144 RPWS1041PV WARRIOR 1 2 PAL STANDARD RES BLACK WHITE VARIFOCAL CAMERA KIT 228 RPWS1043PF WARRIOR 1 2...

Page 12: ...1 2 4 6 7 8 3 5 12 WS3 Exploded Diagram...

Page 13: ...KIT 370 RPWS3046A WARRIOR 3 4 ULTRA HI RES COLOR AUTO IRIS VARIFOCAL CAMERA KIT 486 PAL BOARD CAMERAS RPWS3041PF WARRIOR 3 4 PAL STANDARD RES BLACK WHITE FIXED CAMERA KIT 144 RPWS3041PV WARRIOR 3 4 PA...

Page 14: ...charges The limited warranty stated in these product instructions is subject to all of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Prod...

Reviews: