Moog Videolarm QSDP Instructions Manual Download Page 5

-  -

Use the formula below to select 
the correct power supply for 
cameras connected in parallel 
(positive to positive, negative to 
negative):

Total current for a 4 VAC 
system:

TOTAL CURRENT = (0mA x total number of cameras)   Example: 0mA x  total cameras = 1010mA
Note: 0mA is camera plus power supply

CAMERAS

VOLTAGE

CURRENT

POWER

        1

24 VAC/VDC

102mA

2.5W

        2

24 VAC/VDC

210mA

5W

        3

24 VAC/VDC

331mA

7.9W

        4

24 VAC/VDC

487mA

10.9W

CABLE AND POWER GUIDELINES

This chart shows the proper current needed for power supplies for Q-View Series 
cameras. Use Class 2 Power only. Input voltage must be 
24 VAC/VDC.

Power Supply Cable Maximum Length (feet/meters)

CAMERAS

TOTAL LOAD POWER SUPPLY

24 AWG

22 AWG

18 AWG

16 AWG

1

2.5W

24 VAC/VDC

1718/523

2733/833 6909/2106 10985/3348

2

5W

24 VAC/VC

834/254

1327/404 3356/1023

5335/1626

3

7.9W

24 VAC/VDC

529/161

842/256

2129/649

3385/1032

4

10.9W

24 VAC/VDC

359/109

572/174

1447/441

2300/701

NOTE:

 The above table is based on a "worst-case" power supply. Using a regulated or switching power supply can increase your cable 

            distance. Videolarm recommends using our 

PS4

 power supply, or a CSA/UL listed Class 2 power supply.

Video Cable Maximum Length (feet/meters)

Cable Type

RG-59

RG-6

RG-11

Wire Gauge

23 AWG* 18 AWG* 16 AWG*

 Max. Length 750/229

1500/457 2000/610

* Copper clad steel core, 95% braided shield

AWG

250/76 500/152 1000/305 1500/457 2000/610 3000/914

  18

3

Ω

6

Ω

13

Ω

19

Ω

26

Ω

40

Ω

  20

5

Ω

10

Ω

20

Ω

30

Ω

40

Ω

59

Ω

  22

8

Ω

17

Ω

33

Ω

48

Ω

66

Ω

99

Ω

  24

13

Ω

26

Ω

52

Ω

78

Ω

108

Ω

163

Ω

Maximum Length (feet/meters)

The QRH is setup with (2) individual power inputs.  

 

1.  Accessory Power (yellow and green wire)

 

2.  Camera Power (red and orange)

If you wish to provide a single power transformer it is recommended 
that:

1.  Be certain that you know the total power consumption of the hous-
     ing Heaters (25 watts) + Blowers (2 watts) + camera/pan-tilt (not 
     supplied) 

2.  Check the supplied wiring chart to be sure that you have the 
     proper gauge wire for the distance that you intend to run your 
     power wires. 

3.  Bring power to the 3 and 4 position of the power connector (yellow 
     and green wire) 

4.  Two jumpers are provided in the housing packet.  Jumper from the 
     1

st

 position to the 3

rd

 position and from the 2

nd

  position to the 4

th

 

     position of the terminal block.  Be careful not to short between the 
     yellow and green wires.  

22

250
120

89
65
44
35
29
25
31
19
17
16
14
13
12
11
11
10

9
9
8

20

400
180
141

90
70
56
47
40
34
31
28
25
23
21
20
18
17
16
15
14
14

18

600
300
225
130
112

90
75
64
55
50
45
41
37
34
32
30
28
26
25
23
22

16

960
480
358
225
179
143
119
102

85
79
71
65
59
55
51
47
44
42
39
37
35

14

-

800
571
350
285
228
190
163
140
126
114
103

95
87
81
76
71
67
63
60
57

12

-

1300

905
525
452
362
301
258
215
201
181
164
150
139
129
120
113
106
100

95
90

10

-
-

1440

830
720
576
480
411
340
320
288
261
240
221
205
192
180
169
160
151
144

5.5

10
20
30
40
50
60
70
80
90

100
110
120
130
140
150
160
170
180
190
200

Maxim

um distance fr

om transf

ormer to load

Total vA 

consumed

Wire Gauge

                              24k VAC Wiring Distances

The following are the recommended maximum distances for 24 VAC

with a 10% voltage drop (10% is generally the maximum allowable

voltage drop for AC powered devices).

Figure 5

Add 2 jumpers for 
single power input

Summary of Contents for QSDP

Page 1: ...Before attempting to connect or operate this product please read these instructions completely Product Instructions QView Series QSD Outdoor Dome QSDW QSDP 81 IN5362 12 8 05...

Page 2: ...charges The limited warranty stated in these product instructions is subject to all of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Produ...

Page 3: ...l with 4 bolts not provided NOTE Be sure the hardware and the mounting surface can support the weight of the wall mount bracket plus the weight of the housing and drive unit The load will be subjected...

Page 4: ...24 VAC Yellow 4 Accessory Power 24 VAC Green POWER 4 Attach the wires from the wall to the connector provided using the wiring color code chart as a guide 5 Once all wiring connections are made place...

Page 5: ...meters The QRH is setup with 2 individual power inputs 1 Accessory Power yellow and green wire 2 Camera Power red and orange If you wish to provide a single power transformer it is recommended that 1...

Page 6: ...MAY BE NEEDED SEE THE TROUBLESHOOTING SECTION FOR ADJUSTMENT INFORMATION CAMERA SETTINGS HIGH RES BLACK WHITE FIXED AND FIXED VARI FOCAL LENSES There are no user adjustable settings on these units Fi...

Page 7: ...ve the option of transmitting video signals to NVT receivers via unshielded twisted pair cable You must purchase the receiver separately Instructions for connecting the receiver end of the the unshiel...

Page 8: ...DO make sure the pair of wires carrying the video signal is sent as a twisted pair e g the blue white white blue wires twisted together as a pair not a split pair e g blue white conductor part of one...

Page 9: ...k polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at bot...

Page 10: ...ppear to be unusually dim STATIONARY OR SCROLLING HORIZONTAL LINES ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the fac...

Page 11: ...11 2 000 3 250 R 733 2 132 2 981 1 537 5 500 Mounting Template...