Moog Videolarm QFD SERIES Installation And Operation Instructions Manual Download Page 5

Figure 3

Twist and 
Secure

WIRING

1.  Attach the incoming power and accessory wiring using the color code chart below.

1          Camera Power (24 VAC)               

Red

2          Camera Power (24 VAC)               

Orange

3          Accessory Power (24 VAC)          

Yellow

4          Accessory Power (24 VAC)           

Green

CAMERA ADJUSTMENT

1.  Access the cameras by removing the dome. Loosen the locking screws on the lip of 
the dome. 

DO NOT TAKE THESE SCREWS OUT

. Once the screws are loosened, turn 

the dome counter clock-wise until it stops, then pull the dome off (Figure 4). 

Loosen screws only, do 
not remove

Figure 4

Remove dome by twisting 
counterclockwise

CAMERA FOCUSING (FOR EACH CAMERA)

Fixed Lens:

  Loosen the set screw in the lens mount. Manually rotate the lens 

                     until a clear picture is achieved. Once the focus is set, retighten the  
                     set screw (Figure 5).

Figure 5

Set screw

Fixed lens

NOTE: 

Polarity is not important in this unit. 

3.  Bring all wiring through the NPT pipe or bracket. 

4.  Mount the housing assembly to the mounting bracket and housing coupling.  A 
safety cable is included with the housing to temporarily hold it while making wiring 
connections.  Loop the safety cable over one of the set screws on the housing coupling 
(Figure 3).

5.  Make the proper connections to the incoming power (See Wiring section below) and 
attach all BNC connectors to the video in.

6.  Place the finished wiring inside the pendant pipe. Undo the safety cable and twist 
the housing onto the housing coupling.  Secure all (3) setscrews provided on the 
housing coupling (Figure 3 above).

Auto Iris Lens:  

NOTE:  THE AUTO IRIS LENS IS SET AT THE FACTORY. 

             • IF YOU EXPERIENCE VIDEO TOO LIGHT OR DARK 
               AUTO IRIS ADJUSTMENT MAY BE NEEDED.
             

 SEE THE TROUBLESHOOTING SECTION FOR 

             ADJUSTMENT INFORMATION.

Vari-Focal Lens:

  First, adjust the Magnification Lock Screw to the desired 

magnification (telephoto to wide angle).  Tighten the Lock Screw.  Next, adjust the 
Focus Lock Screw until a clear picture is achieved.  Tighten the Lock Screw (Figure 6).

Figure 6

Magnification lock 
screw

Focus lock 
screw

Fixed iris 
vari-focal lens

CAMERA SETTINGS

SERIAL NUMBERS BEGINNING WITH YK

FIXED AND FIXED VARI-FOCAL LENSES. 

There are no user adjustable settings on 

these units (Figure 7).

Figure 7

AUTO IRIS LENSES.

 The dip switches are factory set with AES off and backlight 

compensation on (Figure 8). The auto iris is also set at the factory, but an adjustment 
screw is included for use if needed. See page 10 for instructions on adjusting Auto Iris.

Auto Iris
adjustment 
screw

AES Default Off

Backlight 
Compensation 
Default On

Figure 8

BW Fixed and Vari-Focal

BW Auto Iris

NOTE:

 To determine which camera is used in your unit, locate the serial number 

on the inside of the housing. Match the two letter prefix with the corresponding 
instructions included here for adjustments.

Summary of Contents for QFD SERIES

Page 1: ...outdoor wall mount tinted dome with 2 Day Night cameras 3 9mm auto iris lens QFDWT4 70NA Standard 7 outdoor wall mount tinted dome with 4 Day Night cameras 3 9mm auto iris lens Before attempting to c...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...the screw removed earlier WALL MOUNTING THE QFD 1 A template is included as a guide for mounting the bracket to a wall Choose the desired location for installation and mark the drill holes using the...

Page 5: ...s to the video in 6 Place the finished wiring inside the pendant pipe Undo the safety cable and twist the housing onto the housing coupling Secure all 3 setscrews provided on the housing coupling Figu...

Page 6: ...h is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the ca...

Page 7: ...es have the option of transmitting video signals to NVT receivers via unshielded twisted pair cable You must purchase the receiver separately Instructions for connecting the receiver end of the unshie...

Page 8: ...battery or MOV type protectors Bridge taps are where a twisted pair is connected to two twisted pairs such as an extension phone at home Bridge taps cause reflections as the signal propagates resultin...

Page 9: ...9 25 O ring 96 RSORG11 2 6 Plastic Ring Plugs 30 VL1696 6 7 FD8 PCB 76 FPD8PB 1 8 FD8 Upper Housing Bracket 30 VL1744 1 9 Housing Gasket 96 PSGK05 3 10 Housing Fan 71 VLBL03 1 11 Adapter Bracket In Ho...

Page 10: ...S ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the factory If you experience video too light or dark you can manually a...

Page 11: ...polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both...

Page 12: ...S TOTAL LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 212...

Page 13: ...Mounting Template 2 000 3 250 R 733 2 132 2 981 1 537 5 500...

Page 14: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...

Reviews: