IMPORTANT SAFEGUARDS

SAFETY PRECAUTIONS

UNPACKING

SERVICE

1     Read these instructions.

2    Keep these instructions. 

3    Heed all warnings 

4    Follow all instructions.

5    Do not use this apparatus near water.

6    Clean only with damp cloth.

7    Do not block any of the ventilation openings.  Install in accordance with the   

  manufacturers instructions.

8    Cable Runs- All cable runs must be within permissible distance.

9    Mounting - This unit must be properly and securely mounted to a supporting  

 

  structure capable of sustaining the weight of the unit.

Accordingly:

a.  The installation should be made by a qualified installer.

b.  The installation should be in compliance with local codes.

c.  Care should be exercised to select suitable hardware to install the unit, taking into 

account both the composition of the mounting surface and the weight of the unit. 

10   Do not install near any heat sources such as radiators, heat registers, stoves, or other    

  apparatus ( including amplifiers) that produce heat.

11   Do not defeat the safety purpose of the polarized or grounding-type plug.  A  

 

  polarized plug has two blades with one wider than the other.  A grounding type  

 

  plug has two blades and a third grounding prong.  The wide blade or the third  

 

  prong are provided for your safety.  When the provided plug does not fit into your  

 

  outlet, consult an electrician for replacement of the obsolete outlet.

12   Protect the power cord from being walked on or pinched particularly at plugs,  

 

  convenience receptacles, and the point where they exit from the apparatus.

13   Only use attachment/ accessories specified by the manufacturer.
14   Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer,  

 

  or sold with the apparatus.  When a cart is used, use caution when moving the cart/           
  apparatus combination to avoid injury from tip-over.

15   Unplug this apparatus during lighting storms or when unused for long periods of time.
16   Refer all servicing to qualified service personnel.  Servicing is required when the  

 

  apparatus has been damaged in any way, such as power-supply cord or plug is  

 

  damaged, liquid has been spilled of objects have fallen into the apparatus, the  

 

  apparatus has been exposed to rain or moisture, does not operate normally, or  

 

  has been dropped.

Be sure to periodically examine the unit and the supporting structure to make sure that the integrity 
of the installation is intact. Failure to comply with the foregoing could result in the unit separating 
from the support structure and falling, with resultant damages or injury to anyone or anything struck 
by the falling unit.

Unpack carefully. Electronic components can be 
damaged if improperly handled or dropped. If an item 
appears to have been damaged in shipment, replace
it properly in its carton and notify the shipper.

Be sure to save:
1  The shipping carton and packaging material.

They are the safest material in which to make future 
shipments of the equipment.

2  These Installation and Operating Instructions.

If technical support or service is needed, contact us at 
the following number:

The lightning flash with an arrowhead symbol, 
within an equilateral triangle, is intended to 
alert the user to the presence of non-insulated 
“dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude 
to constitute a risk to persons.

Este símbolo se piensa para alertar al usuario a la presencia 
del “voltaje peligroso no-aisIado” dentro del recinto de los 
productos que puede ser un riesgo de choque eléctrico.

Ce symbole est prévu pour alerter I’utilisateur à la presence 
“de la tension dangereuse” non-isolée dans la clôture de 
produits qui peut être un risque de choc électrique.

Dieses Symbol soll den Benutzer zum Vorhandensein der 
nicht-lsolier “Gefährdungsspannung” innerhalb der 
Produkteinschließung alarmieren die eine Gefahr des 
elektrischen Schlages sein kann.

Este símbolo é pretendido alertar o usuário à presença “di 
tensão perigosa non-isolada” dentro do cerco dos produtos 
que pode ser um risco de choque elétrico.

Questo simbolo è inteso per avvertire I’utente alla presenza 
“di tensione pericolosa” non-isolata all’interno della 
recinzione dei prodotti che può essere un rischio di scossa 
elettrica.

The exclamation point within an equilateral 
triangle is intended to alert the user to 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the appliance.

Este símbolo del punto del exclamation se piensa para 
alertar al usuario a la presencia de instrucciones importantes 
en la literatura que acompaña la aplicación.

Ce symbole de point d’exclamation est prévu pour alerter 
l’utilisateur à la presence des instructions importantes dans 
la littérature accompagnant l’appareil.

Dieses Ausruf Punktsymbol soll den Benutzer zum 
Vorhandensein de wichtigen Anweisungen in der Literatur 
alarmieren, die das Gerät begleitet.

Este símbolo do ponto do exclamation é pretendido alertar o 
usuário à presença de instruções importantes na literatura 
que acompanha o dispositivo.

Questo simbolo del punto del exclamaton è inteso per 
avvertire l’utente alla presenza delle istruzioni importanti nella 
letteratura che accompagna l'apparecchio.

TECHNICAL SUPPORT

AVAILABLE 24 HOURS

1- 800 - 554 -1124

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER ( OR BACK).  NO USER- SERVICE-

ABLE PARTS INSIDE.  REFER SEVICING 

TO QUALIFIED SERVICE PERSONNEL.

Summary of Contents for QFD SERIES

Page 1: ...outdoor wall mount tinted dome with 2 Day Night cameras 3 9mm auto iris lens QFDWT4 70NA Standard 7 outdoor wall mount tinted dome with 4 Day Night cameras 3 9mm auto iris lens Before attempting to c...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...the screw removed earlier WALL MOUNTING THE QFD 1 A template is included as a guide for mounting the bracket to a wall Choose the desired location for installation and mark the drill holes using the...

Page 5: ...s to the video in 6 Place the finished wiring inside the pendant pipe Undo the safety cable and twist the housing onto the housing coupling Secure all 3 setscrews provided on the housing coupling Figu...

Page 6: ...h is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the ca...

Page 7: ...es have the option of transmitting video signals to NVT receivers via unshielded twisted pair cable You must purchase the receiver separately Instructions for connecting the receiver end of the unshie...

Page 8: ...battery or MOV type protectors Bridge taps are where a twisted pair is connected to two twisted pairs such as an extension phone at home Bridge taps cause reflections as the signal propagates resultin...

Page 9: ...9 25 O ring 96 RSORG11 2 6 Plastic Ring Plugs 30 VL1696 6 7 FD8 PCB 76 FPD8PB 1 8 FD8 Upper Housing Bracket 30 VL1744 1 9 Housing Gasket 96 PSGK05 3 10 Housing Fan 71 VLBL03 1 11 Adapter Bracket In Ho...

Page 10: ...S ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the factory If you experience video too light or dark you can manually a...

Page 11: ...polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both...

Page 12: ...S TOTAL LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 212...

Page 13: ...Mounting Template 2 000 3 250 R 733 2 132 2 981 1 537 5 500...

Page 14: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...