Moog Videolarm FDW7 FusionDome Series Installation And Operation Instructions Manual Download Page 5

- 5  -

22

250

120

89

65

44

35

29

25

31

19

17

16

14

13

12

11

11

10

9

9

8

20

400

180

141

90

70

56

47

40

34

31

28

25

23

21

20

18

17

16

15

14

14

18

600

300

225

130

112

90

75

64

55

50

45

41

37

34

32

30

28

26

25

23

22

16

960

480

358

225

179

143

119

102

85

79

71

65

59

55

51

47

44

42

39

37

35

14

-

800

571

350

285

228

190

163

140

126

114

103

95

87

81

76

71

67

63

60

57

12

-

1300

905

525

452

362

301

258

215

201

181

164

150

139

129

120

113

106

100

95

90

10

-

-

1440

830

720

576

480

411

340

320

288

261

240

221

205

192

180

169

160

151

144

5.5

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

Maxim

um distance fr

om transf

ormer to load

Total vA

consumed

Wire Gauge

                              24k VAC Wiring Distances

The following are the recommended maximum distances for 24 VAC
with a 10% voltage drop (10% is generally the maximum allowable
voltage drop for AC powered devices).

The unit is setup with (2) individual power inputs.

1.

Accessory Power (yellow and green wire)

2.

Camera Power (red and orange)

If you wish to provide a single power transformer it is recommended that:

1.  Be certain that you know the total power consumption of the 

housing Heater (25 watts) + Blower (1 watt) + power supply

(not  supplied) 

2.  Check the supplied wiring chart to be sure that you have the 

     proper gauge wire for the distance that you intend to run your 

     power wires. 

3.  Bring power to the 3 and 4 position of the power connector

(yellow and green wire) 

4.  Two jumpers are provided in the housing packet.  Jumper from 

the 1

st

 position to the 3

rd

 position and from the 2

nd

  position to the 

4

th

 position of the terminal block.  Be careful not to short between 

the yellow and green wires.

Figure 5

Add 2 jumpers for 
single power input

Wiring Color Code

Power and Control Inputs

(Outside of housing)

Power and Control Outputs

(Inside of housing)

POWER

1

Camera Power (24 VAC)

Red

2

Camera Power (24 VAC)

Orange

3

Accessory Power (24 VAC)

Yellow

4

Accessory Power (24 VAC)

Green

CONTROL

1

RS-485RXA

Blue

2

RS-485RXB

Violet

3

RS-485TXA

Gray

4

RS-485TXB

White

POWER AND CONTROL LEADS

1

Camera Power (24 VAC)

Red

2

Camera Power (24 VAC)

Orange

3

RS-485RXA

Blue

4

RS-485RXB

Violet

5

RS-485TXA

Gray

6

RS-485TXB

White

Summary of Contents for FDW7 FusionDome Series

Page 1: ...es Installation and Operation Instructions for the following models FDW7 Before attempting to connect or operate this product please read these instructions completely CERTIFIED 81 IN5324 02 02 2009 2...

Page 2: ...of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Product is defective in material or workmanship then written notice with an explanation...

Page 3: ...ctors A 25W heater 25 watts total with a circulation fan is also supplied ELECTRICAL SPECIFICATIONS OUTDOOR ONLY Power 24VAC Class 2 Only 26 watts at 24 VAC accessories Heater 25 watts Blower 1 watt I...

Page 4: ...ra motor and wind 2 The wall mount bracket provided with the FDW7 includes a location for conduit entry If you wish to install conduit to the bracket remove the conduit hole plug Install tting from be...

Page 5: ...d orange If you wish to provide a single power transformer it is recommended that 1 Be certain that you know the total power consumption of the housing Heater 25 watts Blower 1 watt power supply not s...

Page 6: ...32 x 3 8 bolts and star washers Wire as directed by the manufacturer A wiring color code is supplied on page 5 Trinus Sensormatic AD Ultra Delta Dome The Ultra Dome unitized camera requires use of the...

Page 7: ...ket 96 PSGK04 1 28 1 4 x 20 x 375 HH Bolts 90 BTHH39 2 n s 1 4 Flat Washer 92 WSFL01 2 n s 1 4 Split Lock Washer 92 WSSL01 2 Pendant Assembly 28 27 26 25 24 23 22 21 20 19 18 17 INSTALLING VARIOUS MAN...

Page 8: ...8 8 FDW7 FDW7N Exploded View for Replacement Parts 2 1 3 5 4 6 7 9 10 8 14 16 13 8 12 11 SEE PACKET ASSEMBLY Fixed Housings Only Network Version...

Page 9: ...CONNECTION PCB FIXED MODELS RPRH707 MODEL FD7NHB CONNECTION PCB NETWORK MODELS 8 RPFD040 HOUSING HARDWARE 9 RPFD709 HOUSING TOP 10 WM10 WM10 WALL MOUNT 11 RPNET01 NETWORK CAMERA BRACKETS 12 RPNET02 NE...

Page 10: ...10 2 000 3 250 R 733 2 132 2 981 1 537 5 500 Mounting Template...

Page 11: ...n Form at www videolarm com productregistration jsp or complete and mail in the bottom portion of this yer Register your recent Videolarm purchases and bene t from the following Simple and Trouble Fre...

Reviews: