Example of connections for IRON I sauna heaters
U V W N PE
400 V AC 3N
6,0 kW
zum Steuergerät / control unit
20
00
W
20
00
W
20
00
W
Technical specifi cations
Heater power as
per DIN
Heater dimensions
H/W/D in cm
for sauna cabin
volume
Minimum dimensions
of air intake and
exhaust vents
Weight without
rocks and packaging
Stone fi lling
(not included in the
delivery)
electrical
connection
Fuse protection of
controller, A
Connection power
supply - power
extension
Connection control-
ler - heater
6,0 kW
64 / 44 / 33
6 - 8 m³
35 x 4 cm
13 kg
15 kg
400 V 3N AC
50 Hz
3 x 16
5 x 2,5
5 x 1,5
7,5 kW
8 - 12 m³
35 x 5 cm
9,0 kW
9 - 14 m³
35 x 6 cm
All information on cable cross-sections are minimum cross-sections in mm² copper line.
Leakage current: max. 0.75 mA per kW of heating power.
to be used with control units: that comply with the Low-Voltage Directive 2014/35/EU and the standards: DIN EN 60335-1, DIN EN 60335-2-53, DIN EN
62233, DIN EN 62233 Ber.1 and a sauna operation control range up to max. 115°C, and a sensor system with a safety temperature limiter of max. 142°C
.
Attention!
Always connect the neutral wire N.
4
Saunasteuergerät
Control unit
Boîtier de commande
Пульт управления
Saunaheizgerät
Sauna heater
Poêle de sauna
Печь для сауны
5
5
Netz / Mains / Réseau / Сеть
6,0 / 7,5 / 9,0 kW
U V W N PE
400 V AC 3N
7,5 kW
25
00
W
25
00
W
25
00
W
zum Steuergerät / control unit
U V W N PE
400 V AC 3N
9,0 kW
30
00
W
30
00
W
30
00
W
zum Steuergerät / control unit