![Montronix PulseNG Kit Operating Manual Download Page 26](http://html1.mh-extra.com/html/montronix/pulseng-kit/pulseng-kit_operating-manual_1831075026.webp)
OPI-PulseNGKit-en-141106
Version: 2.01
Page 26 of 31
R
0 2 1 , 7 2 5 , 1 * 6 2 / 8 7 , 2 1 6
Operating Manual
PulseNG
Kit
Setting
Meaning
DSP
(Digital Signal Processor)
Peak to peak, Average, Area, RMS (Root Mean Square)
Delay
Range of values 0-100000, in ms.
When the outputs are not set to „Latched“, you can set the length
of time after which the output will be triggered after an error
event.
Latched
When activated, the outputs will be switched until the alarms are
deleted.
When deactivated, the outputs will be switched for the length of
time specified in „Delay“.
LP Filter (Hz)
Low pass filter
Possible settings from 0-1600
DSP Scale
For Area DSP only. Automatically set after teach operations.
Teach multiplier
Figured into the raw signal during teach operations to determine
the limit value.Range of values Upper Limit: 1.1-255 Range of
values Lower Limit: 0.1-0.9
Emergency stop Determines whether exceeding the respective limit will activate
output 4 (Out4) or not.
Alarm count
Number of suppressed alarms in succession.Only when the
alarm count is up, will an alarm output be triggered.
Range of values: 0-65535
Target value
For Area DSP only.
Range of values: 5-80
Table 9: Limit 1-3
Load file
3
Load file
Save file
OK
Cancel
Loads saved scenario from a local file.
Save file
3
Load file
Save file
OK
Cancel
Saves a scenario to a local file.