![montpellier MTG60LS Installation And Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/montpellier/mtg60ls/mtg60ls_installation-and-operating-instructions-manual_1830791009.webp)
9
G30 28-30 12 mbar kW 873 g/h
II2H3+ GB Class:1
NG
G20 20 mbar
LPG
G30/31 23-30/37
mbar
LARGE BURNER
DIA. of INJECTOR (1/100mm)
115
85
NOMINAL RATING (KW)
2,9
3
CONSUMPTION
276 l/h
218,1 g/h
MEDIUM BURNER
DIA. of INJECTOR (1/100mm)
97
65
NOMINAL RATING (KW)
1,75
1,75
CONSUMPTION
166.7 l/h
127,2 g/h
MEDIUM BURNER
DIA. of INJECTOR (1/100mm)
97
65
NOMINAL RATING (KW)
1,75
1,75
CONSUMPTION
166.7 l/h
127,2 g/h
SMALL BURNER
DIA. of INJECTOR (1/100mm)
72
50
NOMINAL RATING (KW)
1
1
CONSUMPTION
95.2 l/h
72,7 g/h
MAIN OVEN BURNER
DIA. of INJECTOR (1/100mm)
115
75
NOMINAL RATING (KW)
2,4
2,4
CONSUMPTION
228,6 l/h
174,5 g/h
GRILL BURNER
DIA. of INJECTOR (1/100mm)
110
69
NOMINAL RATING (KW)
2,2
2,1
CONSUMPTION
209,5 l/h
152,7 g/h