![montpellier MDG600LK Installation And Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/montpellier/mdg600lk/mdg600lk_installation-and-operating-instructions-manual_1830778018.webp)
EN -16-
Injector
Clip
Remove the injectors using a 7mm spanner and replace the injector with the ones from
the spare set. Make sure you use corresponding diameters suitable to the type of gas
that is going to be used, according to the information chart (which is also supplied in
the gas conversion kit).
Adjusting the minimum flame position:
First of all, make sure that the appliance is unplugged from the the mains electrical supply
and that the gas feed is open. The minimum flame position is adjusted with a flat screw
located on the valve. For valves with a flame failure safety device, the screw is located
on the side of the valve spindle and for valves without a flame failure safety device, the
screw is located inside the valve spindle. To make adjusting the flame position easier,
we recommend that you remove the control panel (and the micro switch if your model
has one) during the alteration. The position of the bypass screw must be loosened for
conversion from LPG to natural gas. For conversion from natural gas to LPG, the bypass
screw must be tightened.
Determining the minimum flame position
To determine the minimum position, ignite the burners and leave them on in minimum
position. Remove the knobs because the screws are accessible only when the knobs
are removed. With the help of a small screwdriver, fasten or loosen the bypass screw
by around 90 degrees. When the flame has a length of at least 4mm, the gas is well
distributed. Make sure that the flame does not die out when passing from the maximum
position to the minimum position. Create an artificial wind with your hand toward the
flame to see if the flames are stable. For the oven burner, operate the oven burner at the
Valve with flame failure
device
Bypass screw
Screw(inside the hole)
Valve without flame
failure device