PL38DF* Indoor Gas Fireplace
XG0216 -160215.1
Installation
Figure 14.
Corner (Rigid) installation. (NG Models Only)
Figure 14a.
Corner (Flex) installation. (NG Models Only)
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the
PXT-20 to suit, and attach it to the PEL-45. Slide the fireplace into
position and attach to the termination.
45° or less Corner Installation.
Use a PTO-4 termination and an PFL-1 or PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be
turned to obtain desired degree of angle required but must not
exceed 45°.
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a PFL-18 (f/f) flexible pipe, and a termination with or
without a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
IMPORTANT:
Corner Installation is available for
PL38DF Top Vent Units Only. Ensure
minimum Vertical Venting Height of 40"
is maintained in corner installations.
Note: Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.