![Montigo M40DV-ST Installation & Operation Manual Download Page 14](http://html1.mh-extra.com/html/montigo/m40dv-st/m40dv-st_installation-and-operation-manual_1830662014.webp)
P/N XG0207
Page 14
M40DV-ST See-Thru Gas Fireplace
Installation
Removing and Installing the
Glass Doors
Removing the Louvres
Remove the louvre assemblies (upper and lower) from one side of the
fireplace. Grasp the assembly underneath one of the louvres and up
slightly and pull outwards, as shown in figure 22a.
Remove the side panel by sliding it out and away from the back of the
fireplace. Refer to figure 22b.
Figure 22a. Removing the louvre
assemblies.
Figure 22b. Removing the side panel.
Figure 22c. Removing the door.
Wiring
Gas Control and Pilot Wiring
Figure 21. Wiring for the M40DV-ST-I with Honeywell gas control
and pilot.
M40DV-ST-I
Removing the Doors
To remove the inner doors, simply unscrew the eight (8) machine
screws on the top and bottom of the door.
(See figure 22c).
Door Installation
To re-install the doors, align the door with the screw holes and re-fasten
with all eight machine screws. Ensure that a good seal is maintained.
Re-install the side panels and louvre assemblies by reversing the
above steps.
Figure 20c. When using a tile surround, do not tile over the outside
Cautions:
DO NOT OPERATE THIS FIREPLACE WITH-
OUT THE GLASS DOOR OR WITH A BROKEN
GLASS DOOR.
CAUTION!
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle