background image

Linear Power 

Vent System

LDVPV58

Installation
Operation &
Maintenance

Warning:

Improper installation, adjustment, alteration, 
service or maintenance can cause injury or property 
damage. Refer to this manual. For assistance or 
additional information consult a qualified installer, 
service agency or the  gas supplier.

What To Do If  You Smell Gas:

•   Do not try to light any appliance.
•   Do not touch any electrical switch;  do not use any phone in your building.
•   Immediately call your gas supplier from a neighbor's phone. Follow the gas 

supplier's instructions.

•    If you cannot reach your gas supplier, call the fire department.

For Your Safety:

Do not store or use gasoline 

or other flammable vapors and 

liquids in the vicinity of this or 

any other appliance.

Safety Notice:

Venting Components and the Power 
Vent System can be  extremely hot 
while the fireplaces is on and remain 
hot even after the fireplace has been 
turned off.  Please allow adequate time 
for the venting to cool before servicing 
or maintaining the power vent.

 

Installer:

 

Leave this manual 

with the appliance.

  Consumer: Leave this man-

ual for future reference.

Check local codes and read all 

instructions prior to installation.

Some materials used in the manufacturing process of this product can  

expose you to Benzene which is known in the State of California to  

cause cancer and birth defects or other reproductive harm. For mor e 

information go to www.P65warnings.ca.go v

WARNING

Summary of Contents for LDVPV58

Page 1: ...Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Safety Notice Venting Components and the Power Vent System can be extremely ho...

Page 2: ...nts For example downward vertical vent runs are possible with an electronic ignition system as outlined in the Venting Section Table Of Contents Introduction Before You Begin Minimum clearances of 1 f...

Page 3: ...m for the LDVPV58 Linear Power Venter WARNING Montigo will not be held responsible for any wa ter damage that may occur from not installing the equipment as specified by this document Linear Power Ven...

Page 4: ...ent must be two feet 2 0 Maximum allowable vent run must be reduced by Ten feet 10 0 for every 90 elbow added Deduct ten feet 10 0 of vent length for every one foot 1 0 of vent run traveling in a down...

Page 5: ...framed at 18 X 18 To enclose the service access panel at less than 1 a minimum 30 free air must be supplied at all times 2 Plug the power chord into the available slot in the linear power vent 3 Secur...

Page 6: ...When installing the wiring it must never run above the vent run and it must be at least 1 clear of all venting 1 Clearance BLACK WHITE WHITE BLACK BLACK WHITE GREEN VARIABLE SPEED COMFORT FANS Lights...

Page 7: ...G OPTIONAL STEPPER MOTOR E 6 10 6 W W GREEN BLACK POWER VENT AIR SWITCH ELLOW ELLOW ELLOW ELLOW BLACK GREEN RED BROWN WHITE CPI IPI SWITCH WHITE SW1 Figure 8a Wiring Clearances Wiring Installation Con...

Page 8: ...rmal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive t...

Page 9: ...ocations PTO4 PV TMHIN 36 TMHIN 40 40 1016 14 1 2 367 37 3 4 960 6 1 2 166 2 1 4 57 8 3 4 223 1 4 7 Minimum combustible clearances Termination 12 1 4 310 1 4 7 Minimum combustible clearances Minimum C...

Page 10: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0752 160902...

Reviews: