EDVRSPV Vertical Power Vent System
Part No. XG1302 - 101201.2
f i r e
f e a t u r e
Installation
Figure 1.
Typical Venting Installations.
Venting Installation
External Power Vent System must be used with a gas fireplace
that is equipped with electronic ignition system. When installing
the venting, the installation must adhere to the Vent Installation
Section in the fireplace's Installation Operation and Maintenance
Instructions, as well as the following guidelines:
■Ensure that the planned termination location is acceptable
as shown in Appendix A.
■
Maximum allowed vent run is 100 feet.
Figure 2.
Multi-elbow Venting Installations.
Multi-Elbow Installations
Multi-elbow installations are possible up to a maximum of six 90°
elbows.
V
Restrictor #1
Max V Max Elbows
100’ feet six 90
Elbow 1
Elbow 2
Elbow 3
Elbow 5
Elbow 4
H2
H1
V1
V2
V3
Restrictor #1
Max V1 + H1 + V2 + H2 + V3 + H3 Max Elbows
100’ feet six 90
Installing the Power Vent
Figure 4.
Step 1.
Construct a chase box around the vent penetration with
exterior dimensions of 17"x 17" x 18"MIN in height.
17”
17”
18”
Figure 3.
Downward Venting Installations.
Downward Vertical Venting
Downward venting installations are only possible with gas fire
-
places equipped with electronic ignition system. Battery backup
cannot be used with a power vent system.
Restrictor #1
Max V1 + H1 + D + H2 + V3 Max Elbows
100’ feet six 90
Elbow 1
Elbow 2
Elbow 3
Elbow 5
H1
V1
D = 6’ foot
MAX
V3
H2
Elbow 4
Page 5