background image

Page 11

C38-VF Gas Fireplace

Part No. XG0317

The Warranty

Montigo DelRay Corp. warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, 
there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas 
control valve and fibre logs. Screen, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by Montigo DelRay Corp..
This Warranty only covers Montigo Gas Appliances installed in the United States.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see Montigo DelRay Corp. right of inves-
tigation outlined below). Montigo DelRay Corp. will, at its option, replace or repair defective components of the Gas Appliance manufactured by Montigo DelRay 
Corp. at no charge, and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially 
practical, Montigo DelRay Corp. will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall Montigo DelRay Corp. be responsible for materials, components, or construction 
which are not manufactured or supplied by Montigo DelRay Corp., or for the labour necessary to install, repair or remove such materials, components or construc-
tion. All replacement or repair components will be shipped F.O.B. the nearest Montigo DelRay Corp. factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with Montigo DelRay Corp. installation instructions and local building codes. The Warranty on this 

Montigo Gas Appliance covers only the component parts manufactured by Montigo DelRay Corp.. The use of components manufactured by others with this 
Montigo Gas Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be 
in violation of local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by 
Montigo DelRay Corp. 

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that Montigo DelRay Corp. sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 
expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall Montigo DelRay Corp. be responsible for any incidental or consequential damages caused by defects in its products, whether such damage 
occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by Montigo DelRay Corp. negligence. Some states do 
not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied 
warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied 
warranty lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

Montigo DelRay Corp. reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
Montigo DelRay Corp. Are Not Responsible For Work Done Without Written Consent
Montigo DelRay Corp. shall in no event be responsible for any warranty work done without first obtaining Montigo DelRay Corp. written consent.
Dealers Have No Authority To Alter This Warranty
Montigo DelRay Corp. employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those 
stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, Montigo DelRay Corp. must be notified of the claimed defect in writing or by telephone, as soon as reasonably 
possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifica-
tions, prices and also to discontinue colors, styles and products.

Warranty

Summary of Contents for C38-VF

Page 1: ... exactly a fire or explosion may result causing property damage personal injury or loss of life For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate com bustion and ventilation air must be provided Refer ...

Page 2: ...or servicing an ap pliance must be replaced prior to operating the heater Installationandrepairshouldbedonebyaqualifiedservice person The appliance should be inspected before use and at least annually by a professional service person Morefrequentcleaningmayberequiredduetoexcessive lint from carpeting bedding material etc It is imperative that control compartments burners and air circulating WARNIN...

Page 3: ... fireplace to a combusti ble ceiling within the fireplace enclosure Refer to page 5 Unprotected combustible walls which are perpendicular to the fire place opening must fall within the limits outlined in Figure 7b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection ...

Page 4: ...s own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 13 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 6 Gas line access The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures i...

Page 5: ...D IN ANY WAY to do so restricts the air supply for the control compartments and heat exchanger it also prevents access for servicing controls The face of the fireplace may be painted to match the room decor provided you use a heat resistant paint Decorative facing must not extend past the fireplace opening at all because it will interfere with the access to retainers for removal of screen door Fig...

Page 6: ...e installing the door To re install the door tilt the top edge towards you and line up the tabs of the bottom of the door with the slots on the fireplace Place the tabs into the slots and tilt the top of the door back towards the fireplace as far as it will go Close the latches by hooking Part B onto the groove at the top of the door and pushing Part A down completely Figure 8b Removing the door I...

Page 7: ...Operating Instructions 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you ...

Page 8: ...d service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Operating Instructions Lighting Instructions See page 7 Burner Adjustment The C38 VF is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the centre of the gas control valve S...

Page 9: ...nections are faulty Check wiring diagram figure 11 Main burner will 1 Check wiring see figure 11 not light 2 Check wall switch for proper con nection Figure 13a Wiring for optional air circulating fan kit Wiring for the optional Fan Kit All C38 VF fireplaces may be equipped with an optional fan kit Part no RFK1002 or RFK1003 for circulating heat into the living space Kits are available with manual...

Page 10: ...roduct If they can not supply original replacement part s Call toll free at 1 800 378 3115 Canadian Heating Products Montigo Delray Corp 27342 Gloucester Way Langley BC V4W 4A1 When contacting dealer or Montigo please have the following ready Your name and address Part number and description of part or acces sories to be replaced Model and serial numbers of your heaters Type of Gas used Natural Ga...

Page 11: ...g from the use of any components not manufactured or supplied by Montigo DelRay Corp 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liab...

Page 12: ...XG0317 Rev 0 9 2002 Installed and Serviced by Montigo Del Ray Corp 6955 Salashan Parkway 27342 Gloucester Way Ferndale WA 98248 Langley BC ...

Reviews: