Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), 

including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to 

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) 

or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts 

In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure (or the 

ceiling joist).

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no.

 

DC8

 

manufactured by Carewell 

Electric Technology (Zhongshan) Co.,Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation. 

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

2

© 2014 Monte Carlo Fan Company

11/15/2014

Summary of Contents for 8EER60 Series

Page 1: ... PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 8EER60XXD Series Fan ETL Model NO 8EER60 XXXXX 10 85 kgs 23 87 lbs 3 0 6 4 9 6 4 ...

Page 2: ... the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be installed with an isolating wall control switch WARNING To reduce the risk of fire ...

Page 3: ...tall the 2 outlet box screws securely Hang motor assembly onto the buckle on mounting plate for hands free wiring and safety cable installation Clasp the cable with hook into the buckle on mounting plate as shown in inset For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams...

Page 4: ...screws removed in step 7 Tighten all screws securely Remove set screws from mounting plate Keep screws Lift fan housing up aligning the holes on housing with the holes on mounting plate Reinstall the set screws remove in step 10 Remove the gasket Align the holes of blade bracket blade and the top plate of blade bracket Install blade bracket with blade and top plate by 3 blade screws provided Tight...

Page 5: ...aligning the keyhole slots on the light pan with the preassembled screws on the plate Twist clockwise till lock Reinstall the screw removed in step 14 Tighten all screws securely Remove 3 set screws from side of light pan Keep screws Connect white wire from fan to white wire from LED light kit and then connect blue wire from fan to blue wire from LED light kit Note If you don t want to install the...

Page 6: ...he holes on LED light kit with the holes on light pan Reinstall the set screws removed in step 17 Tighten screws securely Align the threaded rod in blanking plate with the screw hole in light pan and Install it by turning clockwise till tight Install Blanking Plate Blanking plate Threaded rod ...

Page 7: ...Nov 2014 ...

Page 8: ...emote control transmitter and install battery battery provided Replace the cover Note Use 2 1 5V AAA battery Note If not using for long period of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity ON DIM LEARN L CODE COMMON CODE L CODE COMMON CODE ON DIM Universal Mold Learning Mold Dimming Non Dimming Setting The DIM sele...

Page 9: ...eleased Note This remote controller has auto resume function the fan and light will maintain the last setting if power is turned off Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory 2 If fan or light isn t working reset power turn the power off for at least 10 seconds and then turn th...

Page 10: ...DN LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KR...

Reviews: