background image

Loosen the 3 screws with slots and remove the other

3 screws. Save the screws.

Take the last allen screw and align with hole in

the switch housing cap or light kit, then tighten

all 3 allen screws securely.

To remove the top motor cover twist the cover

and remove this will allow acesss to the screw

holes for the blade arms.

Place blade arm over label on the fan body and

tighten the 2 screws in the blade arm to the

fan body. 

9

7

12

8

Place medallion in blade for long blade arm.

Repeat for each blade.   

14

When attaching the second blade and arm to

fan it should go under the first blade as shown

in photo. Repeat for the other blades and arms.

13

Attach long blade arm to medallion with 2

screws, only start screws.  Repeat for each long

blade arm. 

15

Attach the long blade arms to motor after attach-

ing to blade. Tighten screws to motor securely

and repeat for each blade arm. 

Caution

go back

and securely tighen screws in step 15.  

16

Thread wires and safety cable through motor cover.  

17

Place motor cover over 3 screws and twist

cover into position. Take 3 screws removed ear-

lier and replace, tighten all 6 screws securely.

18

Place medallion on side of blade  not marked

this side up.  Flip the blade over and attach

short arm to set of holes that are closest to the

corner of the blade.  The remaining set of holes

is for the long arm. Repeat for each blade.

10

Use this label on the fan body for the first blade arm

starting position. 

Use caution with blade arms and

blades. Any pressure on blade arms or blades

such as holding fan by blades or blade arms can

create problems of blade pitch deviation or

deforming blade arms.

11

Label

Summary of Contents for 5STR52

Page 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5STR52 Fan READ AND SAVE THESE INSTRUCTIONS Total fan weight ...

Page 2: ...andards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cann...

Page 3: ... Repeat for each long blade arm 15 Attach the long blade arms to motor after attach ing to blade Tighten screws to motor securely and repeat for each blade arm Caution go back and securely tighen screws in step 15 16 Thread wires and safety cable through motor cover 17 Place motor cover over 3 screws and twist cover into position Take 3 screws removed ear lier and replace tighten all 6 screws secu...

Page 4: ...no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 26 House Fan Black White Green Black White Green downrod Green Bracket When alligned push screw in glass into the slotted arm from light...

Page 5: ...ghten the screws to secure the Canopy See inset for Keyhole shape 32 To control fan speed select from High Medium or low speed buttons To turn the fan off press the Fan on off button To dim lights press and hold button To turn off light press and quickly release button Press button marked REV to reverse the rotation direction of the fan blades Fan speed control buttons Fan on off Light dimmer for ...

Page 6: ...ure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by ...

Reviews: