Insert downrod into motor yoke. Next, insert

clevis pin through yoke and downrod and secure

with cotter pin. (see inset)

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting

means to prevent power from being switched on ac-

cidentally.  When the service disconnecting means

cannot be locked, securely fasten a prominent warn-

ing device, such  as a tag, to the service panel.

Install canopy and yoke cover over the down-

rod.

1

4

6

Thread wire through downrod with canopy and

yoke cover assembled.

5

3

Outlet box

Wood

Screws

Mounting
Bracket

Secure mounting bracket directly to a joist from

the buliding structure. Use only the appropriate

wood screws and washers included with your

fan. 

Caution

: Wood screws must go through

into the building joist.

Note

:If Installing It In The U.S., Do Not Remove

Knockouts In The Outlet Box

BUILDING

STRUCTURE

METHOD

Carefully lift fan assembly onto mounting

bracket. Rotate fan so that the notch on the

ball engages the ridge in the mounting bracket.

This will allow hands-free wiring. 

8

7

Tighten both yoke set screws to further secure

downrod. 

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note

:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet 

9

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Warning

-Risk of fire, electric shock, or personal in-

jury. The fan in this box may be either directly sup-

ported from a structural framing member of a

building and/or may be mounted to an outlet box

marked acceptable for fan support of of 31.8 kg (70

lbs) or less. Use only the hardware provided with

the fan brace or outlet box.Most outlet boxes com-

monly used for the support of lumminaires may not

be acceptable for fan support and may need to be

replaced. Consult a qualified electrician if in doubt.

Use only the hardware provided with outlet box.

2

OUTLET BOX METHOD 

For Installation 

in The U.S. only

Summary of Contents for 5SI Series Fan

Page 1: ... to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5SI Series Fan Total fan weight UL Model No AC 212 002 18 55 kgs 40 81 lbs ...

Page 2: ... Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do...

Page 3: ...his will allow hands free wiring 8 7 Tighten both yoke set screws to further secure downrod For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are lo...

Page 4: ...nd wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips 11 House Fan Black White Green Black White Green downrod Green Bracket Blue For control of fan and optional light from wall lo cation follow diagram above NOTE A profes sional electrician is recommended for this type of installation 12 Raise the canopy up and align th...

Page 5: ...previously removed 22 Twist into locking position and tighten in screw taken out Also tighten 2 other loosened screws 19 Connect male to female connector securely 20 For Light Kit Installation Only Loosen the decorative cover first it will make it easier to loosen the finial cap and switch cover for light kit installation ...

Page 6: ...e is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Rev...

Page 7: ...Jan 2012 New format Jun 2013 Update for CUL regulation ...

Reviews: