background image

Installation

TooLS ReQuIReD

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

1

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

2

Use metal outlet box suitable for fan support
(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securley
fastened by at least two points to a structural

ceiling member ( a loose box will cause the fan

to wobble). Install the mounting bracket with
the 2 screws provided with the outlet box.

use only the screws provided with the out-

let box.  

3

Loosen the 2 set screws in yoke

for downrod to slip into yoke.

4

Remove the keeper pin and cross pin

from downrod, and save for later

use.

5

Thread canopy and yoke cover on down-

rod. Thread leadwires and safety cable

through the downrod.

Follow inserts

as shown above.

6

Canopy

Yoke cover

Downrod    

Ball

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and

pushed carefully up into the outlet box.

WaRNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning

device, such as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to

the trailing edge of the blade.

WaRNING

: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting

screws provided with the outlet box  (Mounting must support at least 35 lbs.)

WaRNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert for-

eign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WaRNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WaRNING

: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC7067RC manu-

factured by Rhine Electronic Co., Ltd. Suitable for use with solid-state speed controls.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment man-

ufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,

Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

cauTIoN: 

To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

WaRNING: To ReDuce THe RISK oF FIRe, eLecTRIc SHocK, oR INJuRy To peRSoNS,

oBSeRve THe FoLLoWING: ReaD aND Save THeSe INSTRucTIoNS

S

aFeTy

T

IpS

Summary of Contents for 5HNR52

Page 1: ...Owner s Manual Ceiling Fan Installation Instructions ReaD aND Save THeSe INSTRucTIoNS Total fan weight with lights For 5HNR52XXD Series Fans UL Model No 5HNR52 ...

Page 2: ...means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring a...

Page 3: ...n the Transmitter and the Receiver are set to the same position 15 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the o...

Page 4: ...s shutting down till the proper wattage of bulbs are installed Reset the lights by turning off the wall switch bracker or by remote Replace bulbs with the correct wattage bulbs turn the power on Attach the glass to the fan Install the rubber washer and hex nut which removed in step 24 to the thread rod and secure the glass 28 Loosen 2 screws and remove one screw from the light kit plate Keep the r...

Page 5: ... 36 HAND HELD INSTALL Using wrench to remove the light plate from the light fixture by uninstalling the hex nut and lock washer Save the removed parts for later use 30 Place the thread rod provided in hardware pack to the light plate as shown 31 Install the thread rod with the light plate by the lock washer and hex nut which were removed from step 30 32 Align keyslot holes of the light plate and t...

Page 6: ...ight dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FoRWaRD ReveRSe Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fan must be running to reverse ...

Page 7: ...blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in...

Page 8: ...Owner s Manual Instructions pour l installation d un ventilateur de plafond LIRE ET GARDER CES INSTRUCTIONS Poids total du ventilateur Por 5HNR52XXD Serie ventilateur Fans UL Model No 5HNR52 ...

Page 9: ...èce UC7067RC de commande de vitesse de l hélice construit par le Rhin Electronic Cie Ltd approprié pour l usage avec des commandes de vitesse à semi conducteur 13 Ne JAMAIS installer de commutateur en un endroit accessible d une baignoire ou douche 14 Le débit en air de combustion requis pour le fonctionnement en toute sécurité d équipements alimentés par du combustible peut être affecté par la mi...

Page 10: ...à fond La garniture devrait pouvoir se conformer à toute irrégularité du plafond ou de la boîte de sortie de courant 18 Pour un installation selon les normes du Canada le câble de sécurité doit être installé dans les poutres de structure de la maison à l aide des vis de pres sion 3 fournies S assurer que lorsque le câble de sécurité est entièrement déployé les fils électriques sont plus longs que ...

Page 11: ...nt pas avec des ampoules au wattage supérieur à celui nécessaire Deconnecter les lumières en éteignant l interrupteur le disjoncteur ou par télécommande le cas échéant Remplacer les ampoules par de nouvelles au wattage adéquat puis ouvrir le courant Fixer le globe de verre au ventilateur Fixer la rondelle de caoutchouc et l écrou hexagonal à la tige filetée pour stabiliser le globe de verre 28 Des...

Page 12: ...nt plus de 4 bornes et snaping dans l endroit 37 36 Retirer le montant du luminaire de ce dernier en retirant l écrou hexagonal et la rondelle frein à l aide d une clé Conserver les pièces retirées pour un usage ultérieur 30 Fixer la tige filetée fournie dans le paquet à visserie à la plaque du luminaire comme illustré 31 Fixer la tige filetée et le montant du luminaire à l aide de la ron delle fr...

Page 13: ...un cycle de lumineux pour obscurcir à lumineux jusqu à ce que le bouton soit libéré La lumière maintiendra pour la dernière fois le réglage si arrêtée EXPÉDIEZ INVERSE enfoncent le bouton de tour accordent quelques secon des pour que l extérieur change la direction de rotation avec le fonction nement de ventilateur À GRANDE VITESSE VITESSE MOYENNE À VITESSE RÉDUITE ÉVENTEZ OUTRE DU RÉGLAGE ventila...

Page 14: ...es par poids Les étapes suivantes devraient permettre l éliminer presque totale oscillations Inspecter à la recherche d oscillations à la fin de chaque étape 1 Assurez vous que la nervure de la garniture s engage dans l encoche de la rotule de la tige verticale 2 S assurer que toutes les pales sont bien vissées sur les porte pales 3 Sássurer que tous les porte pales sont bien vissées sur le moteur...

Reviews: