Place blade holders onto blades aligning holes

in blade holder with holes in blade.  Make sure

that the side of the blade you select is facing

downward.  Install  3 screws and fiber washers

to back side of blade as shown.  Tighten

screws securely. Repeat this process 4 more

times until all blades are assembled.

Install blades to motor using the 10

motor screws provided.  Tighten screws

securely.

Setting the reverse switch in the

down position will result in downward

airflow and setting the switch in the

up position will result in upward air-

flow.

25

26

Install 2 of  the screws to the side panel

corresponding to the open slotted holes on

the canopy upper rim. Remove the all

thread studs from the lower part of the

mounting bracket.

Lift fan to mounting bracket, aligning the “L”

shape holes with the scresws on the mount-

ing bracket.  Turn the fan  clockwise to lock

in position. Install the 2 canopy mounting

bracket screws from the hardware pack and

tighten securely.

19

24

Hang fan from mounting bracket by

the hands free hook into a closed

hole on the edge of the Canopy.   

20

Hands free hook

Make wire connections to power source using wire nuts
provided.  Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on the
other side of the outlet box.  

23

Connect black and blue wire from fan to Black or (Hot)
wire from house.  Connect White wire from Fan to White
(Neutral) wire from house.  Connect Ground leads from
mounting bracket and downrod to Ground lead from
house.  

Refer to Safety Tips section of manual.

22

House

Fan

Blue 

Black

White

Green

Black

White

Ground

Place the canopy over the yoke screws

aligning the large holes from the canopy

over the remaining screws of the yoke. 

Reinstall the screws previously removed.  

18

Reverse

switch

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note

:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet Box.  

21

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Summary of Contents for 5HM52 ND Series

Page 1: ...s card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5HM52XXND Series Fan Total fan weight with light kit UL Model No AC 552 7 8 kgs 17 16 lbs ...

Page 2: ... If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign o...

Page 3: ... appears on the other side Install the Keeper Pin Tighten the 2 Set screws on the Yoke once the downrod is in place Check motor for shipping stabilizers and re move if present Tread leadwires and safety cable first through the canopy disk Canopy and lastly downrod 5 6 4 Canopy disk Downrod Canopy Yoke Cross Pin Keeper Pin Hang assembled fan from the mounting bracket in stalled to ceiling in previo...

Page 4: ...knurled nuts securely The canopy should adjust for any irregularity in the ceiling or Outlet box 13 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 10 Cover Ring House Fan Blue Black White Green Bla...

Page 5: ...using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 23 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from...

Page 6: ...e lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 31 Locate blue and white wire from the fan marked For light kit Connect blue from fan to black from light and white from fan to white from light by pushing connectors together 32 Attach switch cap to fan by lining up 2 slot ear holes and 1 screw hole and twisting cap Then tig...

Page 7: ... 2013 Monte Carlo Fan Company 11 15 2013 7 Align hole in glass and hole in finial cap to allow the fan speed pull chain to pass through Install finial nut and tighten 36 ...

Page 8: ...bove the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest t...

Page 9: ...Jan 2012 new fornmat Jul 2013 Update for CUL regulation Nov 2013 5HM52XXND ...

Reviews: