2/8/2012
© 2011 Monte Carlo Fan Company
3
1
Before you begin installing the fan, Switch
power off at Service panel and lock service
disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot
be locked, securely fasten a prominent
warning device, such as a tag, to the
service panel.
2
Before installing this fan make sure the
outlet box is properly installed to the house
structure. To reduce the risk of fire, electric
shock, or personal injury, mount to outlet
box or supporting system acceptable for fan
support.
(Mounting must support at least 35 lbs.)
3
Use metal outlet box suitable for fan support
and use only the screws provided with the
outlet box (must support 35 lbs). Before
attaching fan to outlet box, ensure the outlet
box is securely fastened by at least two points
to a structural ceiling member ( a loose box
will cause the fan to wobble). Remove the
two outlet box screws provided with the box,
aligning the holes of the mounting bracket
with the holes of the outlet box. Re-install the
2 outlet box screws securely.
4
Loosen the 2 screws on the yoke to
allow down rod to slip into yoke.
5
6
Place canopy over downrod.
Remove cross pin from downrod,
and save for later use.
8
7
Thread the leadwires and safety cable
through the downrod.
P l a c e y o k e c o v e r o v e r
downrod.
9
Insert downrod into the yoke on top of fan
body. Align the hole in the downrod with the
hole in the yoke. Insert cotter pin through
yoke and downrod until point appears on the
other side